AJBLS · Lens · Method Development and Validation of Acyclovir by UV Spectrophotometric Method

PDF

Article · Volume 14, Issue 3 · pp. 780–786

Method Development and Validation of Acyclovir by UV Spectrophotometric Method

Badavathu Raja1, Mohammad Amatul Haq-Kubra2, Gunaganti Lakshmi Prasanna2, Bura Naga Sri2, Bakkidul Islam2, Maram Chinnaeswaraiah3

  1. 1Department of Pharmaceutical Analysis, Anurag Pharmacy College, Kodad, Telangana, INDIA.
  2. 2Anurag Pharmacy College, Kodad, Telangana, INDIA.
  3. 3Department of Pharmacognosy, Anurag Pharmacy College, Kodad, Telangana, INDIA.

Abstract

Background: Acyclovir, an antiviral agent active against herpes simplex virus types I and II and varicella zoster, is widely used in pharmaceutical formulations. Existing pharmacopoeial methods employ non-aqueous titration or spectrophotometry at 254 nm. However, simple, rapid, and validated UV spectrophotometric methods for routine estimation are limited.Objectives: To develop and validate a simple, sensitive, and cost-effective UV spectrophotometric method for the quantitative estimation of Acyclovir in bulk and pharmaceutical dosage forms as per ICH Q2 (R1) guidelines.Materials and Methods: Acyclovir standard stock solution (1000 µg/mL) was prepared in distilled water. Working solutions (0.5-30 µg/mL) were scanned, and the wavelength of maximum absorbance (λmax ) was determined at 254 nm. Calibration curves were plotted in the concentration range of 0.5-30 µg/mL. Method validation was performed for assay, linearity, precision, accuracy, robustness, ruggedness, Limit of Detection (LOD), and Limit of Quantification (LOQ).Results: The method showed excellent linearity (R²=0.996) in the concentration range of 0.5-30 µg/mL. Accuracy studies demonstrated percentage recoveries between 98.94% and 100.86%, within pharmacopeial limits (99-101%). Precision studies indicated low %RSD (<2%) for repeatability, intra-day, and inter-day analysis. Robustness and ruggedness tests confirmed stability under small deliberate variations in wavelength, analyst, and conditions. The method exhibited low LOD and LOQ values, indicating high sensitivity.Conclusion: The developed UV spectrophotometric method is simple, rapid, precise, accurate, robust, and cost-effective. It can be successfully applied for routine quality control and estimation of Acyclovir in bulk and tablet dosage forms.

Keywords: Acyclovir; Diazo Coupling; p-Dimethylaminobenzaldehyde; Spectrophotometric determination; Acyclovir; Temperature and Coupling Reaction Time

The full text of this article is available as a PDF. Open the PDF.