Article

Method Development and Validation of Acyclovir by UV Spectrophotometric Method

Badavathu Raja1★, Mohammad Amatul Haq-Kubra2, Gunaganti Lakshmi Prasanna2, Bura Naga Sri2, Bakkidul Islam2, Maram Chinnaeswaraiah3★ Corresponding author

  1. 1Department of Pharmaceutical Analysis, Anurag Pharmacy College, Kodad, Telangana, INDIA.
  2. 2Anurag Pharmacy College, Kodad, Telangana, INDIA.
  3. 3Department of Pharmacognosy, Anurag Pharmacy College, Kodad, Telangana, INDIA.

CORRESPONDENCE

Badavathu Raja

Department of Pharmaceutical Analysis, Anurag Pharmacy College, Kodad, Telangana, INDIA.

rajabadavathu@gmail.com

Received: 13-10-2025; Revised: 24-11-2025; Accepted: 02-12-2025.

Volume 14, Issue 3 · pp. 780–786 · PUBLISHED · DOI: 10.5530/ajbls.20250033

View on AJBLS original site ↗

ABSTRACT

Background: Acyclovir, an antiviral agent active against herpes simplex virus types I and II and varicella zoster, is widely used in pharmaceutical formulations. Existing pharmacopoeial methods employ non-aqueous titration or spectrophotometry at 254 nm. However, simple, rapid, and validated UV spectrophotometric methods for routine estimation are limited. Objectives: To develop and validate a simple, sensitive, and cost-effective UV spectrophotometric method for the quantitative estimation of Acyclovir in bulk and pharmaceutical dosage forms as per ICH Q2 (R1) guidelines. Materials and Methods:Acyclovir standard stock solution (1000 µg/mL) was prepared in distilled water. Working solutions (0.5-30 µg/mL) were scanned, and the wavelength of maximum absorbance (λmax ) was determined at 254 nm. Calibration curves were plotted in the concentration range of 0.5-30 µg/mL. Method validation was performed for assay, linearity, precision, accuracy, robustness, ruggedness, Limit of Detection (LOD), and Limit of Quantification (LOQ).Results: The method showed excellent linearity (R²=0.996) in the concentration range of 0.5-30 µg/mL. Accuracy studies demonstrated percentage recoveries between 98.94% and 100.86%, within pharmacopeial limits (99-101%). Precision studies indicated low %RSD (<2%) for repeatability, intra-day, and inter-day analysis. Robustness and ruggedness tests confirmed stability under small deliberate variations in wavelength, analyst, and conditions. The method exhibited low LOD and LOQ values, indicating high sensitivity. Conclusion: The developed UV spectrophotometric method is simple, rapid, precise, accurate, robust, and cost-effective. It can be successfully applied for routine quality control and estimation of Acyclovir in bulk and tablet dosage forms.

KEYWORDS

Open in new tab

REFERENCES

As published

Showing references and in-text citations exactly as published.

    Cite this article

    SELECT FORMAT

    Raja, B., Haq-Kubra, M. A., Prasanna, G. L., Sri, B. N., Islam, B., & Chinnaeswaraiah, M. (). Method Development and Validation of Acyclovir by UV Spectrophotometric Method. Asian Journal of Biological and Life sciences, 14(3), 780–786. https://doi.org/10.5530/ajbls.20250033