Article · Volume 57, Issue 3S · pp. s798–s804
Stability-Indicating Reversed Phase-HPLC Method Development and Validation for Estimation of Phenylephrine in Bulk and Tablet
Shruti Srivastava1, Suneela Dhaneshwar2, Neha Kawathekar3
- 1Department of Pharmaceutical Chemistry, Amity Institute of Pharmacy-Lucknow, Amity University (Uttar Pradesh), Noida, Uttar Pradesh, INDIA.
- 2Department of Pharmaceutical Chemistry, Amity Institute of Pharmacy, Amity University (Maharashtra), Mumbai, Maharashtra, INDIA.
- 3Department of Pharmacy, SGSITS, Indore, Madhya Pradesh, INDIA.
Abstract
Background: This study is aimed to develop a validated stability-indicating method of a nasal decongestant phenylephrine hydrochloride in bulk and tablet.Materials and Methods: A sensitive, accurate, and specific reversed-phase stability indicating HPLC method was developed and validated by following ICH guidelines, for the estimation of Phenylephrine Hydrochloride (PHE) in bulk and tablet. On Luna® 5µm C18 column (250 × 4.6mm), the isocratic separation was achieved using mobile phase of 5mM ammonium acetate (pH 4.7): methanol (80:20; v/v) with a flow rate of 1 mL/min and a column temperature at 30°C. The proposed method was able to produce good separation of the drug and its degradation products with sharp peaks. The quantification was done at 272 nm by photodiode array detection.Conclusion: It was discovered that the phenylephrine hydrochloride was resilient to photolytic and thermal degradation, but degraded under acid, base, and oxidative stress conditions. The developed method was found to be linear, robust, and accurate and can be successfully applied for identification, quantitative determination, and monitoring of the stability of phenylephrine in bulk and tablet dosage forms.
Keywords: Chromatogram; High performance liquid chromatography; Decongestant; Degradation; ICH guidelines
The full text of this article is available as a PDF. Open the PDF.