Article · Volume 9, Issue 1S · pp. s24–s28
Method Validation of Esomeprazole Analysis in Human Plasma using High Performance Liquid Chromatography–Photodiode Array
Yahdiana Harahap1, Ahmad Erik Baskara1, Harmita h1
- 1Faculty of Pharmacy, University of Indonesia, UI Depok Campus, Depok, 16424, INDONESIA.
Abstract
Objective: This research aimed to develop sensitive, simple, and selective methods for determination of esomeprazole in human plasma using lansoprazole as internal standard by high performance liquid chromatography.Method: The analytical separation was performed on C-18 column (Waters, Sunfire™ 5 μm; 250 x 4.6 mm), column temperature 40°C. The mobile phase used acetonitrile - phosphate buffer pH 7.6 (40: 60% v/v) with a flow rate of 1.00 mL/min; and photodiode array detector at a wavelength of 300 nm. Esomeprazole and lansoprazole were extracted by liquid-liquid extraction using dichloromethane.Results: The method had a chromatographic run time of 10 min and linear calibration curve over the range of 5.0-450 ng/mL with a correlation coefficient (r) of 0.999 or better. The sensitivity, specificity, linearity, precision and accuracy, recovery and stability were validated for esomeprazole in human plasma.Conclusion: The results of validation fulfilled the acceptance criteria of validation method based on EMEA Bioanalytical Guideline 2011.
Keywords: Esomeprazole; HPLC; Optimization; Validation; Plasma
The full text of this article is available as a PDF. Open the PDF.