Article

Novel Index Value of Fibrinogen and Glucose in Risk Assessment with HOMA-IR

Kuppusamy Subramaniam Elango1★, Narasimhan Banu2, Swaminathan Vijayalakshmi3★ Corresponding author

  1. 1Vels Institute of Science, Technology and Advanced Studies, Chennai. Scientific Officer, HSEG/HISD/OHS, IGCAR, Kalpakkam Tamil Nadu, INDIA.
  2. 2Assistant Professor, Department of Botany, Bharathi Women’s College (Autonomous), Chennai, Tamil Nadu, INDIA.
  3. 3Professor, Department of Biotechnology, VELS University, Pallavaram, Chennai Tamil Nadu, INDIA.

CORRESPONDENCE

Kuppusamy Subramaniam Elango

Vels Institute of Science, Technology and Advanced Studies, Chennai. Scientific Officer, HSEG/HISD/OHS, IGCAR, Kalpakkam Tamil Nadu, INDIA.

kselango1968@gmail.com

Received: 15-02-2021; Revised: 16-04-2021; Accepted: 21-04-2021.

Volume 10, Issue 1 · pp. 76–80 · PUBLISHED · DOI: 10.5530/ajbls.2021.10.12

View on AJBLS original site ↗

ABSTRACT

In Type 2 diabetes, Insulin resistance leads to microvascular and macrovascular complications. Early diagnosis prevents this complication. Previous studies confirm the association between fibrinogen level and insulin sensitivity but compound effect of glucose and fibrinogen risk levels are not analysed in insulin resistant non-insulin-dependent diabetes. Present study deriving model index with the combination of fibrinogen, glucose value (FiG) and investigating whether linked to HOMA-IR, triglyceride, and glucose (TyG) index also finding alternative index in type 2 diabetes insulin-resistant patients. The study includes 30 Type 2 Diabetic patients and 20 Nondiabetics (control). Fasting serum samples were used to measure Insulin, Triglyceride. A fasting plasma sample was used to measure Glucose and Fibrinogen. The Fasting blood sugar, HOMA-IR, TyG index and the Fibrinogen-Glucose (FiG) novel index between Non-diabetic and Diabetic at a significance of p value < 0.001 level. Serum insulin level shows a significant difference between Non-diabetic and Diabetic at p value < 0.05 level. Also, the receiver operating characteristic curve (ROC) explains the FiG novel index with the good value of are under the curve by 0.877. The FiG index value shows a good correlation with HOMA-IR, and TyG index value also predicts the value of a variable on the value of another variable through linear regression. Hence, it could be suggested for beneficial index value in type 2 diabetes insulin resistant and its complication like cardiovascular diseases.

KEYWORDS

Open in new tab

REFERENCES

As published

Showing references and in-text citations exactly as published.

    Cite this article

    SELECT FORMAT

    Elango, K. S., Banu, N., & Vijayalakshmi, S. (). Novel Index Value of Fibrinogen and Glucose in Risk Assessment with HOMA-IR. Asian Journal of Biological and Life sciences, 10(1), 76–80. https://doi.org/10.5530/ajbls.2021.10.12