Article · Volume 58, Issue 2S · pp. s532–s542
A Validated Simple, Rapid and Accurate RP-HPLC Approach for Measuring Vardenafil Hydrochloride Trihydrate in Bulk Drugs and Medicinal Formulations
Ganesh Ramesh Gadekar1, Rajendra Chandrashekhar Doijad2, Namdeo Ramhari Jadhav2, Somnath Devidas Bhinge3
- 1Department of Pharmaceutics, Appasaheb Birnale College of Pharmacy-Sangli, South Shivaji Nagar, Sangli, Maharashtra, INDIA.
- 2Krishna Institute of Pharmacy, Krishna Vishwa Vidyapeeth (Deemed to be University), Malkapur, Karad, Maharashtra, INDIA.
- 3Department of Pharmaceutical Chemistry, Rajarambapu College of Pharmacy, Kasegaon, Walwa, Sangli, Maharashtra, INDIA.
Abstract
Background Shortcomings in current analytical methods characterized by time-consuming procedures, limited sensitivity, and high costs associated with reagents and instruments, influence the research background. Objectives The goal of this research was to find a simple, fast, and accurate way to discern and quantify substances in bulk drugs and finished products at the utmost minimal levels of detection and quantification. Materials and Methods The methodology involved using a C18 column then a solvent mixture comprising 0.1% orthophosphoric acid and acetonitrile in an 80:20 proportion delivered at 1 mL/min-1 and observed at 247 nm with a UV detector. Results Following rigorous verification in line with ICH guidelines, the technique revealed several notable features. It revealed rapidity with a retention time of 2.53 min, accurate with average recoveries ranging from 99.20% to 100.43%, precision as demonstrated by a relative standard deviation below 2%, specificity, and a highly linear correlation coefficient of 0.999 between 0.0025 to 6 μg mL-1. Additionally, the method displayed remarkable sensitivity, detecting concentrations as low as 56.91 ng mL-1 and a quantification limit of 172.44 ng mL-1. Conclusion This tested RP-HPLC method has a unique mix of speed, accuracy, and high sensitivity that makes it possible to accurately measure Vardenafil hydrochloride trihydrate, even at nanogram levels. This surpasses established techniques and offers a cost-effective solution for pharmaceutical quality control and analysis.
Keywords: RP-HPLC; Vardenafil hydrochloride Trihydrate; LOD; Nanogram
The full text of this article is available as a PDF. Open the PDF.
