Quantitative Reverse-phase High-performance Liquid Chromatographic Method for the Quantification of Raltegravir Potassium in Bulk and Dosage Forms
Sonam Patel1, Krishnaveni Nagappan1★, Gouru Santhosh Reddy1, Gullapalli Kowmudi1★ Corresponding author
- 1Department of Pharmaceutical Analysis, JSS College of Pharmacy, Ooty, [A Constituent College–JSS Academy of Higher Education and Research], The Nilgiris, Tamilnadu, INDIA.
CORRESPONDENCE
Krishnaveni Nagappan
Department of Pharmaceutical Analysis, JSS College of Pharmacy, Ooty, [A Constituent College–JSS Academy of Higher Education and Research], The Nilgiris, Tamilnadu, INDIA.
Received: 06-06-2019; Revised: 26-06-2019; Accepted: 28-06-2019.
Volume 11, Issue 3 · pp. 274–278 · PUBLISHED · DOI: 10.5530/jyp.2019.11.55
ABSTRACT
Objectives:The aim of this present study is to develop an accurate, precise and linear Reverse-phase High-performance Liquid Chromatographic (RPHPLC) method for the estimation of raltegravir potassium in the bulk and pharmaceutical dosage form. Methods: The chromatographic system employs a reverse phase shim-pack C18 column, (150 x 4.6 mm; 5 μ) using the mobile phase acetonitrile: (0.05 M) ammonium acetate buffer, (pH -4 adjusted with glacial acetic acid) in the proportion of 50:50 v/v, delivered at a flow rate of 0.8 ml/min with the detection wavelength of 271 nm. Results: The developed method resulted in the retention of raltegravir at 4.31 min. Raltegravir potassium exhibited linear relationship (r 2 > 0.9999) over the analytical range 10-50 μg/ml. The precision was exemplified by a relative standard deviation of 1.60 %. The percentage recovery was found to be in the range of 100-102 %, during accuracy studies. The Limit of Detection (LOD) and Limit of Quantitation (LOQ) was found to be 0.104 µg/ml and 0.315 µg/ml, respectively. Conclusion: An accurate, precise and linear RP-HPLC method was developed and validated for the quantitative estimation of raltegravir potassium in (20 mg, 50 mg) tablet as per ICH guidelines and hence it can be used for the routine analysis in various pharmaceutical industries.
KEYWORDS
REFERENCES
As publishedShowing references and in-text citations exactly as published.
Cite this article
SELECT FORMAT
Patel, S., Nagappan, K., Reddy, G. S., & Kowmudi, G. (). Quantitative Reverse-phase High-performance Liquid Chromatographic Method for the Quantification of Raltegravir Potassium in Bulk and Dosage Forms. Journal of Young Pharmacists, 11(3), 274–278. https://doi.org/10.5530/jyp.2019.11.55
