Article

Simultaneous Analytical Method Development of 6-Mercapto purine and 6-Methylmercaptopurine in Plasma by High Performance Liquid Chromatography-Photodiode Array

Yahdiana Harahap1★, Nurul Azizah1, Rizka Andalusia2, Supandi s1★ Corresponding author

  1. 1Faculty of Pharmacy Universitas Indonesia, Depok, INDONESIA.
  2. 2Department of Research and Development of Dharmais Hospital National Cancer Center, Jakarta, INDONESIA.

CORRESPONDENCE

Yahdiana Harahap

Faculty of Pharmacy Universitas Indonesia, Depok, INDONESIA.

yahdiana14@gmail.com

Received: 05-01-2017; Revised: 27-01-2017; Accepted: 14-02-2017.

Volume 9, Issue 1S · pp. s29–s34 · PUBLISHED · DOI: 10.5530/jyp.2017.1s.8

View on JYP original site ↗

ABSTRACT

Objective: 6-Mercaptopurin is antineoplastic drug that is included in antimetabolite group and is used in acutelymphoblastic leukemia medication. 6-Mercaptopurin is inactive pro-drug that will be metabolized into metabolites. One of its metabolites is 6-methylmercaptopurine. This study is aimed to optimize the analytical conditions and perform validation for the analysis of 6-mercapto purine and 6-methylmercaptopurine in plasma. Method:Separation was per formed using Waters 2996 HPLC, C18 SunfireTMcolumn (5μm, 250 x 4.6 mm) with the mobile phase containing water-methanol-acetonitrile with gradient elution, and detected at 303 nm. 5-Fluorouracil was used as internal standard. Plasma extraction was done by liquid-liquid extraction using dichloromethane. Result:The method was linear at concentration range of 2.0 – 200.0 ng/mL with r > 0.9991 for 6-mercaptopurine and 20 – 2000 ng/mL with r > 0.9993 for 6-methylmercaptopurine. Accuracy and precision within-run and between-run fulfill the acceptance criteria with % RE and relative standard deviation (% RSD) ≤ 20% (LLOQ) and ≤ 15% (QC samples). 6-Mercaptopurine and 6-methyl mercaptopurine was stable in plasma at least for 21 days when stored at -20ºC. Conclusion:The bio-analytical method was sensitive, selective and all the parameters fulfilled the acceptance criteria of the EMA Bio-analytical Method Validation Guideline, 2011.

KEYWORDS

Open in new tab

REFERENCES

As published

Showing references and in-text citations exactly as published.

    Cite this article

    SELECT FORMAT

    Harahap, Y., Azizah, N., Andalusia, R., & s, S. (). Simultaneous Analytical Method Development of 6-Mercapto purine and 6-Methylmercaptopurine in Plasma by High Performance Liquid Chromatography-Photodiode Array. Journal of Young Pharmacists, 9(1S), s29–s34. https://doi.org/10.5530/jyp.2017.1s.8