Communication

Rapid Development and Validation of Improved Reversed‑Phase High‑performance Liquid Chromatography Method for the Quantification of Mangiferin, a Polyphenol Xanthone Glycoside in Mangifera indica

P Naveen1★, HB Lingaraju2, K Shyam Prasad3★ Corresponding author

  1. 1Analytical Research and Development, Vidya Herbs Pvt. Ltd., Bengaluru, Karnataka, INDIA.
  2. 2Analytical Research and Development, Vidya Herbs Pvt. Ltd. Bengaluru, Karnataka; Phytochemistry Lab, Vidya Herbs Pvt. Ltd., Bengaluru, Karnataka, INDIA.
  3. 3Phytochemistry Lab, Vidya Herbs Pvt. Ltd., Bengaluru, Karnataka, INDIA.

CORRESPONDENCE

P Naveen

Analytical Research and Development, Vidya Herbs Pvt. Ltd., Bengaluru, Karnataka, INDIA.

naveen2384@gmail.com

Volume 9, Issue 2 · pp. 215–219 · PUBLISHED 1 April 2021 · DOI: 10.4103/0974-8490.204652

View on PR original site ↗

ABSTRACT

Mangiferin, a polyphenolic xanthone glycoside from Mangifera indica, is used as traditional medicine for the treatment of numerous diseases. The present study was aimed to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC) method for the quantification of mangiferin from the bark extract of M. indica. RP-HPLC analysis was performed by isocratic elution with a low-pressure gradient using 0.1% formic acid: acetonitrile (87:13) as a mobile phase with a flow rate of 1.5 ml/min. The separation was done at 26°C using a Kinetex XB-C18 column as stationary phase and the detection wavelength at 256 nm. The proposed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification, and robustness by the International Conference on Harmonisation guidelines. In linearity, the excellent correlation coefficient more than 0.999 indicated good fitting of the curve and also good linearity. The intra- and inter-day precision showed <1% of relative standard deviation of peak area indicated high reliability and reproducibility of the method. The recovery values at three different levels (50%, 100%, and 150%) of spiked samples were found to be 100.47, 100.89, and 100.99, respectively, and low standard deviation value <1% shows high accuracy of the method. In robustness, the results remain unaffected by small variation in the analytical parameters, which shows the robustness of the method. Liquid chromatography–mass spectrometry analysis confirmed the presence of mangiferin with M/Z value of 421. The assay developed by HPLC method is a simple, rapid, and reliable for the determination of mangiferin from M. indica.

KEYWORDS

Open in new tab

REFERENCES

As published

Showing references and in-text citations exactly as published.

    Cite this article

    SELECT FORMAT

    Naveen, P., Lingaraju, H., & Prasad, K. S. (2021). Rapid Development and Validation of Improved Reversed‑Phase High‑performance Liquid Chromatography Method for the Quantification of Mangiferin, a Polyphenol Xanthone Glycoside in Mangifera indica. Pharmacognosy Research, 9(2), 215–219. https://doi.org/10.4103/0974-8490.204652