Article

Stability-Indicating RP-HPLC Method for the Quantification of Paliperidone in Bulk and Solid Dosage Form to Establish Validation and Stability Indicating Parameters

Sadashivaiah Rudragangaiah1, Rohith Ganapathi Bhatta1, Satheesha Babu Birur Kotappa1★★ Corresponding author

  1. 1Department of Pharmaceutics, Government College of Pharmacy, P Kalinga Rao Road, Subbaiah Circle, Bengaluru, Karnataka, INDIA.

CORRESPONDENCE

Satheesha Babu Birur Kotappa

Department of Pharmaceutics, Government College of Pharmacy, P Kalinga Rao Road, Subbaiah Circle, Bengaluru, Karnataka, INDIA.

bksatishbabu@gmail.com

Received: 22-02-2019; Revised: 17-05-2019; Accepted: 04-09-2019.

Volume 53, Issue 4S · pp. s691–s698 · PUBLISHED 2019 · DOI: 10.5530/ijper.53.4s.166

View on IJPER original site ↗

ABSTRACT

Objectives: In the present research work, stability indicating reverse phase high performance liquid chromatography method was developed and validated for the quantification of paliperidone in bulk and solid dosage form. Materials and Methods: The chromatographic separation of paliperidone was carried out using Phenomenex, Gemini NX, Octadecyl silane column (150x4.6 mm, 5 µm, particle size) with the mobile phase consisting of methanol: acetonitrile: 0.15% v/v triethylamine in water (pH 6) in the ratio of 50:20:30 v/v, flow rate was determined at 1 ml/min. UV detection wavelength was observed at 237 nm. Method validation and stress testing was carried out as per ICH guidelines Q2 (R1) and Q1A (R2) to demonstrate the suitability and specificity of the method. Results: The developed method had shorter retention time of 3.2 min. The RSD for system, method and intermediate precision in all instrumental condition was found to be less than 2% and the mean recovery was found to be 100.64%. Linearity range was obtained at concentration range of 7.5-150 µg/ml with a regression coefficient (R2) of 0.999. Detection and quantification limits for paliperidone were found to be 0.14 and 0.42 µg/ml, respectively. The developed method could separate the potential degradation products from the analyte peak. Conclusion: The results of validation were found to be satisfactory in all tested validation parameters suggested that the developed method is specific, precise, accurate and robust. Hence, this method would be applied for quantification of paliperidone in bulk and solid dosage form.

KEYWORDS

Open in new tab

REFERENCES

As published

Showing references and in-text citations exactly as published.

    Cite this article

    SELECT FORMAT

    Rudragangaiah, S., Bhatta, R. G., & Kotappa, S. B. B. (2019). Stability-Indicating RP-HPLC Method for the Quantification of Paliperidone in Bulk and Solid Dosage Form to Establish Validation and Stability Indicating Parameters. Indian Journal of Pharmaceutical Education and Research, 53(4S), s691–s698. https://doi.org/10.5530/ijper.53.4s.166