Fabrication of Poly (Sebacic acid-co-ricinoleic-ester anhydride) with β-cyclodextrin-loaded Doxorubicin Implants and in vitro Characterization
Nagaraja Sreeharsha1,9★, Jagadeesh G Hiremath2, Bandar E Al-Dhubiab1, Girish Meravanige3, Ranjith Kumar Karnati4, Mahesh Attimarad1, Anroop B Nair1, Katharigatta N Venugopal1,10, Mohamed A Morsy1,8, Shinu Pottathil5, Saleemmulla Khan6, Nagashekhara Molugulu7★ Corresponding author
- 1Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa, SAUDI ARABIA.
- 2Department of Pharmaceutics, PA College of Pharmacy, Mangalore, Karnataka, INDIA.
- 3Department of Biomedical Sciences, College of Medicine, King Faisal University, Al-Ahsa, SAUDI ARABIA.
- 4Department of Chemistry, College of Science, King Faisal University, Al-Ahsa, SAUDI ARABIA.
- 5Department of Biomedical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa, SAUDI ARABIA.
- 6Department of Pharmacognosy, PA College of Pharmacy, Mangalore, Karnataka, INDIA.
- 7School of Pharmacy, Monash University, Jalan Lagoon Selatan, Bandar Sunway, Selangor, MALAYSIA.
- 8Department of Pharmacology, Faculty of Medicine, Minia University, El-Minia 61511, EGYPT.
- 9Department of Pharmaceutics, Vidya Siri College of Pharmacy, Off Sarjapura Road, Bangalore, INDIA.
- 10Department of Biotechnology and Food Technology, Durban University of Technology, Durban, SOUTH AFRICA.
CORRESPONDENCE
Nagaraja Sreeharsha
Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Ahsa, SAUDI ARABIA.
Received: 29-02-2020; Revised: 30-03-2020; Accepted: 30-03-2020.
Volume 54, Issue 3 · pp. 826–834 · PUBLISHED 2020 · DOI: 10.5530/ijper.54.3.135
ABSTRACT
Background: Doxorubicin is an excellent molecule for the formation of biodegradable implants using the poly (sebacic acid-co-ricinoleic-ester anhydride) 70:30 w/w (poly[SARA] 70:30 w/w PSRA 7/3) polymer. Methods: The cylindrical implants were successfully produced by means of hot melt extrusion. We used differential scanning calorimetric (DSC) and X-ray diffraction (XRD) methods to identify the melting state and crystal type of blank and drug-loaded implants. A study was conducted on PSRA 7/3 w/w blank and drug-loaded implants for in vitro hydrolytic degradation. The drug present in the remaining sample was estimated. Results: The hydrolytic degradation rate of the 10% w/w (F2)-loaded implant was relatively low when compared with the 20% w/w (F3) implant. Discussion: In vitro drug release studies illustrated that the drug-release rate was faster in association with increasing amounts of doxorubicin in the implant.
KEYWORDS
REFERENCES
As publishedShowing references and in-text citations exactly as published.
Cite this article
SELECT FORMAT
Sreeharsha, N., Hiremath, J. G., Al-Dhubiab, B. E., Meravanige, G., Karnati, R. K., Attimarad, M., Nair, A. B., Venugopal, K. N., Morsy, M. A., Pottathil, S., Khan, S., & Molugulu, N. (2020). Fabrication of Poly (Sebacic acid-co-ricinoleic-ester anhydride) with β-cyclodextrin-loaded Doxorubicin Implants and in vitro Characterization. Indian Journal of Pharmaceutical Education and Research, 54(3), 826–834. https://doi.org/10.5530/ijper.54.3.135
