Analysis of ICH-Q3D Endorsed Elemental Impurities in Macrolide Antibiotics by ICP-MS
Ravisankar Mathesan1★, Alexandar Sekar2, Senthil Kumar Raju3, Kumar Mohan2, Venkateswarlu Bendi Sri1★ Corresponding author
- 1Department of Pharmacy, Vinayaka Mission’s College of Pharmacy, Vinayaka Mission’s Research Foundation (Deemed to be University), Salem, Tamil Nadu, INDIA.
- 2Department of Pharmaceutical Analysis, Vinayaka Mission’s College of Pharmacy, Vinayaka Mission’s Research Foundation (Deemed to be University), Salem, Tamil Nadu, INDIA.
- 3Department of Pharmaceutical Chemistry, Swamy Vivekanandha College of Pharmacy, Tiruchengode, Tamil Nadu, INDIA.
CORRESPONDENCE
Ravisankar Mathesan
Department of Pharmacy, Vinayaka Mission’s College of Pharmacy, Salem-636308, Tamil Nadu, INDIA.
Received: 12-02-2023; Revised: 23-04-2023; Accepted: 14-08-2023.
Volume 57, Issue 4 · pp. 1219–1225 · PUBLISHED 2023 · DOI: 10.5530/ijper.57.4.145
ABSTRACT
Aim: The objective of this study was to determine the amount of twenty-three elemental impurities in Azithromycin API. A rapid, selective, precise, accurate and sensitive approach for detecting elemental impurities in Azithromycin API was developed and validated using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). Background: Conventional analytical methods used in pharmacopoeia’s are less sensitive and accurate to detect heavy metal impurities. Concerning this issue, a new inductively coupled plasma mass spectrometry-based method was developed and validated as a different choice to investigate the Elemental impurities in an Azithromycin API sample. Materials and Methods: In the present research work, test samples were prepared with microwave supported acid digestion. Results: After a sequence of trails, the mixture of nitric acid, hydrochloric acid, and hydrogen peroxide (4 mL: 1 mL: 0.5 mL) with the accepted recovery range was chosen for the Azithromycin API's digestion. Conclusion: According to ICH and USP 233 guidelines, the proposed technique was successfully validated using ICP-MS for linearity, precision, accuracy, LOD, LOQ, and ruggedness.
KEYWORDS
REFERENCES
As publishedShowing references and in-text citations exactly as published.
Cite this article
SELECT FORMAT
Mathesan, R., Sekar, A., Raju, S. K., Mohan, K., & Sri, V. B. (2023). Analysis of ICH-Q3D Endorsed Elemental Impurities in Macrolide Antibiotics by ICP-MS. Indian Journal of Pharmaceutical Education and Research, 57(4), 1219–1225. https://doi.org/10.5530/ijper.57.4.145