Article

Stability Indicating RP-UPLC Method for Impurity Profiling of Darunavir and Ritonavir in Fixed Dose Drug Combination Product

Munish Buch1,2★, Hasit Vaghani1★ Corresponding author

  1. 1Department of Chemistry, Mehsana Urban Institute of Sciences, Ganpat University, Ganpat Vidyanagar, Kherva, Mehsana, Gujarat, INDIA.
  2. 2Department of Analytical Development, Emcure Pharmaceuticals Limited, Uvarsad Square, S G. Highway, Adalaj, Gandhinagar, Gujarat, INDIA.

CORRESPONDENCE

Munish Buch

Department of Chemistry, Mehsana Urban Institute of Sciences, Ganpat University, Ganpat Vidyanagar, Kherva, Mehsana-384012, Gujarat, INDIA.

munish.buch10@gmail.com

Received: 19-04-2023; Revised: 17-09-2023; Accepted: 06-01-2024.

Volume 58, Issue 2S · pp. s558–s565 · PUBLISHED Apr-Jun 2024 · DOI: 10.5530/ijper.58.2s.58

View on IJPER original site ↗

ABSTRACT

Background The goal of the proposed study was to develop and validate stability indicating mass compatible reverse phase UPLC method for impurity profiling of Darunavir Ethanolate and Ritonavir degradation impurities in fixed-dose drug combination products. Materials and Methods The optimized chromatographic condition includes use of Zorbax Bonus C18 column (150x2.1 mm, 1.8 μm) with mobile phase A (Buffer (55): Methanol (45)) and mobile phase B (Acetonitrile: (30) and Methanol (70)), flow rate of 0.22 mL/min and detection at 240 nm with gradient program of 50 min. The method was validated as per ICH quality guideline Q2 (R1) including specificity by forced degradation study to confirm suitability for intended use. Results The observed retention time for Darunavir was 11.4 min and for Ritonavir was 30.0 min. The Limit of Quantitation (LOQ) for all degradation impurities found is 0.05%, equivalent to the reporting threshold level. The method was found linear and accurate in the range of LOQ to 150% with an observed range of % accuracy of 90.1 to 106.3 for all known impurities. The method was found precise based on less than 10.0% RSD and robust for deliberate changes. Considering the use of a volatile mobile phase, the method can be applied for LC-MS-based analysis for mass identification. Conclusion The developed UPLC method was applied for impurity profiling during the release and stability study of Darunavir Ethanolate and Ritonavir in fixed-dose drug combination products.

KEYWORDS

Open in new tab

REFERENCES

As published

Showing references and in-text citations exactly as published.

    Cite this article

    SELECT FORMAT

    Buch, M., & Vaghani, H. (2024). Stability Indicating RP-UPLC Method for Impurity Profiling of Darunavir and Ritonavir in Fixed Dose Drug Combination Product. Indian Journal of Pharmaceutical Education and Research, 58(2S), s558–s565. https://doi.org/10.5530/ijper.58.2s.58