Review

A Simultaneous Quantification of Four Potential Genotoxic Impurities Purinediol Hydrochloride, N7-Isomer, Monoalkyl Contaminant and Diacetyl Purine Present in Penciclovir Using LC-MS/MS

Nagasurendra Reddy Varampati★, Devanna Nayakanti★ Corresponding author

  1. 1Department of Chemistry, College of Engineering, Jawaharlal Nehru Technological University, Anantapur, Ananthapuramu, Andhra Pradesh, INDIA.

CORRESPONDENCE

Nagasurendra Reddy Varampati

Research Scholar, Department of Chemistry, College of Engineering, Jawaharlal Nehru Technological University, Anantapur, Ananthapuramu-515002, Andhra Pradesh, INDIA.

vnsreddy99@gmail.com

Received: 10-07-2023; Revised: 19-12-2023; Accepted: 05-07-2024.

Volume 58, Issue 4 · pp. 1255–1266 · PUBLISHED Oct-Dec 2024 · DOI: 10.5530/ijper.58.4.138

View on IJPER original site ↗

ABSTRACT

Background: Penciclovir is a medication for antiviral therapy for curing different kinds of herpes virus infections. The four contaminants are the starting materials of Penciclovir which are present at a trace level in the drug in which one of its impurities is its isomer. Purinediol Hydrochloride, N7-Isomer, Monoalkyl contaminant and Diacetyl Purine are the four potential impurities present in the drug. Materials and Methods: The separation was achieved in the Zorbax SB C8 column using a gradient elution of 10 mM Ammonium bicarbonate in water as a buffer and a mixture of Methanol and Acetonitrile in the ratio of 20:80 v/v at a flow rate of 0.6 mL/min at 40°C. The Agilent Q-TOF 6540 series instrument was used in positive polarity in the scan range of 50-100 m/z. The sensitive and rapid Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS) technique was developed for the quantification of four impurities present in the drug. Results: Various validation parameters have been studied. The correlation coefficients of impurities and their linearity values are quite satisfactory within the examined range. The proposed method was sensitive in the linearity range from 0.6 ppm to 12.0 ppm. Conclusion: This method can be used to identify the impurities in Penciclovir drug substances during manufacturing.

KEYWORDS

Open in new tab

REFERENCES

As published

Showing references and in-text citations exactly as published.

    Cite this article

    SELECT FORMAT

    Varampati, N. R., & Nayakanti, D. (2024). A Simultaneous Quantification of Four Potential Genotoxic Impurities Purinediol Hydrochloride, N7-Isomer, Monoalkyl Contaminant and Diacetyl Purine Present in Penciclovir Using LC-MS/MS. Indian Journal of Pharmaceutical Education and Research, 58(4), 1255–1266. https://doi.org/10.5530/ijper.58.4.138