RP-HPLC Single Advance Method with Validation Studies for Imipramine Hydrochloride and its Intermediates
Vighnesh Pradeep Nalawade1, Faiz Hussain Sayyed1, Sonali Ramgopal Mahule1★, Pandurang Maruti Chavhan2, Nitin Rathod3★ Corresponding author
- 1Amity School of Applied Science, Amity University Mumbai, Mumbai-Pune Expressway Bhatan, Somathne, Panvel, Maharashtra, INDIA.
- 2Faculty of Life, Health and Allied Sciences, ITM Vocational University, Vadodara, Gujarat, INDIA.
- 3IPCA Laboratories, Chemical Research Division, Kandivali (W), Mumbai, Maharashtra, INDIA.
CORRESPONDENCE
Sonali Ramgopal Mahule
Assistant Professor, Department of Chemistry, ASAS, Amity University Mumbai, Mumbai-Pune Express Bhatan, Somathne, Panvel Mumbai-410206, Maharashtra, INDIA. and sonali.mahule@gmail.com
Received: 01-12-2023; Revised: 24-03-2024; Accepted: 12-07-2024.
Volume 59, Issue 1S · pp. s283–s291 · PUBLISHED Jan-Mar 2025 · DOI: 10.5530/ijper.20256210
ABSTRACT
Background A quantifiable method has been developed to determine the key starting material, its intermediates and known impurities in the presence of Imipramine Hydrochloride in the final API of a synthetic laboratory sample. This newly developed Reverse-Phase High-Performance Liquid Chromatography (RP-HPLC) method is, facile, specific and reliably practical. Materials and Methods The separation column employed was Inertsil ODS-3 C18 with a mobile phase comprised of (A) 0.1% OPA (pH adjusted to 3.2) and (B) acetonitrile. Mobile phase A is a 100% buffer solution. Acetonitrile was used as mobile phase “B” and mobile phase B was used as 100% organic Solvent. The analytes were detected at 220 nm using a UV detector where the flow rate of the mobile phase was kept at 1.0 mL min-1 and the gradient program was set as T/% B: 0/30, 5/30, 10/80, 12/80, 15/30, 20/30 with a fixed flow rate of 1.0 mL min-1. Results According to the regulatory standards advised by the ICH, the performance of this method is best agreed upon by all the important parameters. The approach used in the present work can be used for process development and determining the purity of associated compounds of Imipramine Hydrochloride, key starting material (2,2-dinitro-1,2-diphenylene ethane), intermediate-1 (2-2-diamino-1,2-diphenyl ethane diphosphate) and intermediate-2 (iminodibenzyl) all in a single method. Conclusion This newly developed and validated method will save time and create ease by preventing the development of different methods for analyzing intermediates and impurity profiling.
KEYWORDS
REFERENCES
As publishedShowing references and in-text citations exactly as published.
Cite this article
SELECT FORMAT
Nalawade, V. P., Sayyed, F. H., Mahule, S. R., Chavhan, P. M., & Rathod, N. (2025). RP-HPLC Single Advance Method with Validation Studies for Imipramine Hydrochloride and its Intermediates. Indian Journal of Pharmaceutical Education and Research, 59(1S), s283–s291. https://doi.org/10.5530/ijper.20256210
