Article

Development and Validation of a Simple and Robust Bioanalytical Method to the Quantification of Tafamidis in Human Plasma using LC-MS/MS

Shashipal Aitha1, Subramani Devaraju1,2★, Kiran Kumar Tatapudi3, Geereddy Mahesh Kumar Reddy3, Tiruveedhula Somasekhar4★ Corresponding author

  1. 1Department of Chemistry, School of Applied Science and Humanities, Vignan’s Foundation for Science, Technology and Research, Vadlamudi, Guntur, Andhra Pradesh, INDIA.
  2. 2Department of Chemistry, Polymer Engineering Laboratory, PSG Institute of Technology and Applied Research, Neelambur, Coimbatore, Tamil Nadu, INDIA.
  3. 3Discovery Analytical R&D, Aragen Life Sciences Pvt. Ltd., Nacharam, Hyderabad, Telangana, INDIA.
  4. 4Department of Humanities & Sciences, Vidya Jyothi Institute of Technology, Aziz nagar Gate, Chilkur Balaji Road, Himayat Sagar Rd, Hyderabad, Telangana, INDIA.

CORRESPONDENCE

Subramani Devaraju

Department of Chemistry, School of Applied Science and Humanities, Vignan’s Foundation for Science, Technology and Research, Vadlamudi, Guntur, Andhra Pradesh, INDIA.

subudeva@gmail.com

Received: 21-05-2026; Revised: 04-06-2026; Accepted: 17-08-2026.

Volume 60, Issue 4S · pp. s1716–s1723 · PUBLISHED 2026 · DOI: 10.5530/ijper.20262396

View on IJPER original site ↗

ABSTRACT

Objectives: Amyloid diseases are a rare class of disorders that have gained significant attention for therapeutic advancements. Among the key proteins implicated, transthyretin plays a central role in the progression and clinical symptoms of these diseases. Tafamidis, an approved therapeutic agent, has demonstrated considerable efficacy in mitigating symptoms associated with transthyretin-related amyloid conditions. Despite its clinical significance, robust bioanalytical methodologies for the accurate quantification of Tafamidis in biological matrices remain limited. Materials and Methods: This study focuses on the development and validation of a precise bioanalytical method to quantify Tafamidis in human plasma using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS). The method was calibrated over a range of 5-4000 ng/mL, with chromatographic separation performed using an isocratic mobile phase on a Gemini NX C18 column. Mass transitions were optimized at 307.400 → 262.400 for Tafamidis and 313.900 → 270.000 for Tafamidis-13C6. A liquid-liquid extraction approach ensured efficient recovery of Tafamidis from plasma. Results and Discussion: Validated per USFDA regulatory guidelines, the method demonstrated excellent precision, accuracy, and stability, with correlation coefficients exceeding 0.99 and recovery rates reaching 70%. Stability was confirmed for up to 10 days in matrix and aqueous samples. Conclusion: This robust, validated method offers high reliability and suitability for analytical applications and quantitative clinical investigations involving Tafamidis.

KEYWORDS

Open in new tab

REFERENCES

As published

Showing references and in-text citations exactly as published.

    Cite this article

    SELECT FORMAT

    Aitha, S., Devaraju, S., Tatapudi, K. K., Reddy, G. M. K., & Somasekhar, T. (2026). Development and Validation of a Simple and Robust Bioanalytical Method to the Quantification of Tafamidis in Human Plasma using LC-MS/MS. Indian Journal of Pharmaceutical Education and Research, 60(4S), s1716–s1723. https://doi.org/10.5530/ijper.20262396