Article

Simultaneous Estimation of Moxifloxacin and Tolfenamic Acid: Development and Validation of UV-visible, HPLC, and HPTLC Methods

Seema A. Gosavi1★, Pratiksha D. Bornare1, Jyoti B. Tangde2, Aditi S. Kulkarni3★ Corresponding author

  1. 1Department of Quality Assurance Technique, Sanjivani College of Pharmaceutical Education and Research, At Sahajandnagar, Shinganapur, Kopargaon, Ahmednagar, Maharashtra, INDIA.
  2. 2Department of Pharmaceutical Chemistry , PDEA’s College of Pharmacy, Hadapsar, Pune, Maharashtra, India.
  3. 3Department of Pharmacognosy, Smt. Kashibai Navale College of Pharmacy, Kondhwa, Pune, Maharashtra, India.

CORRESPONDENCE

Seema A. Gosavi

Department of Quality Assurance Technique, Sanjivani College of Pharmaceutical Education and Research, Sahajandnagar, Shinganapur, Kopargaon, Ahmednagar-423603, Maharashtra, INDIA.

seemagosavi@gmail.com

Received: 13-04-2026; Revised: 07-05-2026; Accepted: 26-06-2026.

Volume 16, Issue 4 · pp. 1451–1456 · PUBLISHED Oct-Dec 2026 · DOI: 10.5530/ijpi.20260122

View on IJPI original site ↗

ABSTRACT

Objectives This research emphasizes validating the HPLC, HPTLC, and UV-visible techniques for the simultaneous quantitative measurement of Moxifloxacin (MOX) and Tolfenamic Acid (TA) in veterinary formulations. Materials and Methods The UV spectrophotometric analysis was performed at 291 nm for moxifloxacin and 272 nm for tolfenamic acid. For HPLC, chromatographic separation was achieved using a gradient technique on a reverse-phase C18 ODS column (250×4.6 mm, 5 µm particle size) with a mobile phase comprising 2% orthophosphoric acid and an acetonitrile with ratio of 80:20, with a 1 mL/min flow rate. Detection was accomplished at 254 nm. For HPTLC, separation was performed on pre-coated silica gel 60 F254 plates using a mobile phase of acetonitrile: water: formic acid: methanol:30% ammonia (8:1:1:1:2 v/v). Densitometric assessment for separate zones was performed at 230 nm. Results The HPLC analysis of the current method exhibits the linearity range from 2 to 12 µg/mL for moxifloxacin and 1 to 6 µg/mL for tolfenamic acid in HPLC, 8 to 20 µg/spot for moxifloxacin and 4 to 9 µg/spot for tolfenamic acid in HPTLC, and 6 to 42 µg/mL for MOX and 3 to 21 µg/mL for TA in UV spectrophotometry. The methods were found to be accurate; recovery was achieved from 98 to 102%. The Relative Standard Deviation (RSD) for precision was found to be less than 2%. Conclusion The proposed methods were successfully applied to the determination of MOX and TA in both bulk and veterinary tablet formulations. The methods were validated in accordance with ICH Q2-(R1) guidelines.

KEYWORDS

0% READ

FULL TEXT

INTRODUCTION

According to EU regulation 2017/625, the analytical techniques are used for official control of veterinary drugs in animals and animal products, primarily involving liquid chromatography, gas chromatography, ultraviolet, fluorescence, or Mass Spectrometry (MS) detection. The use of multiple liquid chromatography techniques for various chemicals has long been standard practice for detecting antibiotics and other veterinary medication residues (Khalifa and Shikoray, 2024).

Moxifloxacin, a fourth-generation fluoroquinolone antibiotic, is used to cure bacterial infections in veterinary medicine. It is particularly effective against gram-positive bacteria and targets topoisomerase II and topoisomerase IV enzymes (Meena et al., 2019). It is a synthetic compound structurally characterized by a 4-oxo-1,4-dihydroquinoline-carboxylic acid moiety (National Center for Biotechnology Information [NCBI], 2025). Tolfenamic acid, a conventional anti-inflammatory agent, inhibits Cyclooxygenases (COX) enzymes, which play an important role in prostaglandin synthesis. In addition to its anti-inflammatory effects, it is an anticancer agent which acts through apoptosis (programmed cell death) (Feldman et al., 2018). It also has potential effects on NF-κB, which is a protein complex that controls DNA transcription. Moreover, tolfenamic acid may lower the expression of Alzheimer's Disease (AD)-related genes and their products, potentially reduce the pathological burden, and improve cognitive function (Kankaanranta, 1993).

This article primarily highlights the method development for the simultaneous estimation of moxifloxacin and tolfenamic acid using UV, HPLC, and HPTLC methods. Few methods have been previously reported for the simultaneous estimation of this combination, including an RP-HPLC stability study (Ahmed et al., 2024), a simple RP-HPLC method (Mali et al., 2025), a UV-spectrophotometric method for MOX (Shende et al., 2022; Gul et al., 2015), and a UV method for TA assay (Tarkase et al., 2012). However, no method has been reported for the combination of moxifloxacin and tolfenamic acid using UV, HPLC, and HPTLC techniques. Therefore, the current study focuses on the development and validation of methods for the concurrent estimation of this combination using UV, HPLC, and HPTLC.

MATERIALS AND METHODS

Materials (Chemicals and Reagents)

Moxifloxacin (MOX) was obtained from Cure worth Drugs and Intermediates Pvt. Ltd., and Tolfenamic Acid (TA) was obtained from Mehta Pharmaceuticals Industries, Mumbai. The fixed-dose combination of MOX (1500 mg) and TA (750 mg), marketed as Duromoxi Bolus, was sourced from Macquor Pharma, Panipat. Analytical-grade sodium hydroxide, formic acid, toluene, and ammonia were purchased from Modern Industries, Nashik, India. Acetonitrile and Methanol (HPLC grade) were obtained from Finar Limited, Gujarat, India, and ethyl acetate was purchased from Fine Chemicals, Mumbai, India.

Instrumentation

The UV-visible method was developed using a Shimadzu UV-visible double-beam spectrophotometer (UV-1800), with UV Probe Software for data analysis, and a pair of quartz cells (1 cm). The RP-HPLC method was developed using a Shimadzu Prominence-i LC-203ºC 3D HPLC system with PDA detector having 20 μL injection volume. The C18 ODS column, dimension (250 × 4.6 mm, 5 μm) and Lab Solutions software were used for computational analysis.

The HPTLC instrumentation consisted of a sample applicator with a 100 μL syringe volume. TLC scanning was performed using TLC software, while spot detection was done using a Crystal-3 UV cabinet. A Canon IXUS digital camera was used for capturing images of the TLC plates. For image documentation, the Easy Doc II Mini Photo Documentation System (Model 2019) was employed. The weighing of samples was performed using analytical balance (Shimadzu AY120), and sonication was accomplished using SIDILU Ultrasonic Bath.

Methods

Preparation of standard stock solution

For UV analysis, 10 mg each of MOX and TA standards were weighed correctly and transferred 100 mL volumetric flasks. Then it was dissolved in 0.1 N NaOH. The volumes were then adjusted to the mark with 0.1 N NaOH to get 100 µg/mL of MOX and TA each.

For HPLC and HPTLC, 10 mg of MOX and 5 mg of TA were weighed accurately individually and transferred to separate 10 mL volumetric flasks. 5 mL of solvent was added to each flask to make up the volume, to prepare 1000 ppm solution. It was sonicated to aid dissolution.

Preparation of sample solution

Ten tablets were accurately weighed, and the average weight was calculated. An amount equivalent to 100 mg of MOX and 50 mg of TA was transferred to a 100 mL of volumetric flask. The solution was diluted to 50 mL with a suitable solvent and sonicated for 15 min.

Development of spectrometric and chromatographic methods

For UV method

To perform UV analysis, concentrations were prepared ranging from 2 to 14 µg/mL using 0.1 N NaOH for both MOX and TA. The absorbance of these solutions was measured at 272 nm (iso-absorptive point) and 291 nm (λmax of MOX). Absorptive values were then calculated using the calibration curve for MOX.

The concentrations of the two drugs in the mixture were calculated in 0.1 N NaOH at 272 nm and 291 nm using the equations below.

Where,

A1, A2 are absorbance of mixture at 272 nm and 291 nm.

ax1 and ay1 are absorptivity of MOX and TA at 272 nm and ax2 and ay2 at 291 nm respectively.

For HPLC Method

A C18 ODS column was used as the stationary phase. The mobile phase consisted of Methanol: Acetonitrile (80:20 v/v). The pH of the mobile phase was adjusted to 4.0 using orthophosphoric acid. The flow rate was 1 mL/min. The mobile phase was filtered using Whatman filter paper and degassed prior to use. Wavelength detection was accomplished at 254 nm.

For HPTLC Method

The solutions were spotted using sample applicator syringe on an aluminum percolated silica F254 plate in the form of bands with an aetron 100 μL. The plate spotting was developed in an Aetron glass chamber of 10 × 10 cm previously saturated for 20 min with the mobile phase acetonitrile: water: formic acid: methanol: ammonia. 30% (8:1:1: 1:2) (v/v). The developed spots were scanned at 254 nm at a scanning speed of 10 mm/sec.

RESULTS AND DISCUSSION

Validation of the proposed method

The current method was validated following the (ICH Q2R1) guidelines, (Ahmed et al., 2015, International Conference on harmonization [ICH], 2005) the detailed summary of regression and validation parameters for UV, HPLC and HPTLC for MOX and TA is provided in Table 1.

Table 1: Summary of regression and validation parameters for UV, HPLC & HPTLC.
SamplesUVHPLCHPTLC
RangeR2LODLOQRangeR2LODLOQRangeR2LODLOQ
MOX6-42 μg/mL0.9993.086.382-12 μg/mL0.9980.62.132-112 µg/µL0.9920.22.4
TA3-21 μg/mL0.9999.3819.721-6 μg/mL0.9990.50.71.92-6.72 µg/µL0.9930.60.8

System suitability parameter

The performance of the proposed method was evaluated by assessing the system's overall suitability. Key parameters were considered such as theoretical plates, tailing factor, and percentage Relative Standard Deviation (%RSD).

Linearity (Preparation of calibration curves)

For an UV-visible spectrophotometry, the linearity was performed using 6-42 µg/mL concentrations for MOX and 3-21 µg/mL for TA. The calibration curve was constructed by plotting absorbance versus concentration as shown in Table 2 and Figure 1.

Figure 1: UV scan of MOX and TA showing absorptive points.
Table 2: Results of linearity data of MOX & TA in UV Spectroscopy.
Conc. of solution (µg/mL)MOX at 291 nmMOX at 272 nmConc. of solution (µg/mL)TA at 291 nmTA at 272 nm
Mean Abs±SD (n=3)% RSDMean Abs±SD (n=3)% RSDMean Abs±SD (n=3)% RSDMean Abs ±SD (n=3)% RSD
60.560±0.00050.1030.211±0.0010.47330.164±0.0021.2667340.193±0.0010.897
121.023±0.0010.0970.418±0.0010.23960.396±0.0030.7575760.293±0.0031.095
181.562±0.0010.0730.632±0.0020.32990.580±0.0112.0545960.386±0.0030.934
242.083±0.0010.0480.830±0.0010.183120.796±0.0020.3158930.496±0.0020.533
302.574±0.0030.1241.098±0.0010.091150.984±0.0020.2114080.595±9.0030.635
363.0323±0.00050.0191.303±0.0020.153181.196±0.0020.2212170.684±0/0071.096
423.575±0.0030.1051.514±0.0020.185211.393±0.0040.3289720.784±0.0020.265

The linearity for HPLC was performed by using 2-12 µg/mL of MOX and 1-6 µg/mL of TA. These solutions were prepared using standard stock solutions. The calibration curve was constructed by plotting peak areas versus concentrations. The optimized chromatogram is shown in Figure 2.

Figure 2: Optimized Chromatogram of MOX TA in HPLC.

HPTLC calibration curve was prepared using 8 to 20 (µg/uL) spots for MOX and 4 to 9 (µg/uL) for TA. The plates were dried and ran through the mobile phase chamber (the mobile phase chamber was saturated for 25 min). Finally, the spots were scanned through a UV cabinet, and volumes were noted from TLC software. The calibration curve was plotted by taking conc. vs. volume. Figure 3 shows the optimized TLC plate for MOX and TA and Figure 4 represents the lane profile graph of MOX and TA. The detailed linearity for all method data is given in Table .

Figure 3: Optimized TLC plate MOX & TA.
Figure 4: Lane profile graph of MOX & TA.

Method precision

The precision is degree of agreement between a set of measurements taken from several homogenous samples under specified conditions is known as precision. Intraday and interday precision served as evidence of the analytical method's accuracy.

Intra-day precision

Three sets of different concentrations as low, middle, and high were prepared for intraday precision. After an hour, each set of samples was injected into the system on the same day, and the chromatogram was recorded to determine the reaction peak. The percentage RSD was calculated for every concentration.

Inter-day precision

Inter-day precision study, was accomplished using three sets of concentrations (low, middle, and high). Each set was analyzed on different days. The chromatograms were recorded for each injection, and the peak responses for each concentration set were determined on each day. The % RSD (Relative Standard Deviation) was calculated for each concentration level to assess the precision across the different days. Table 3 represents the interday and intraday precision data of MOX and TA conducted for UV, HPLC and HPTLC.

Table 3: Interday and Intraday precision in UV, HPLC & HPTLC (n*=6 determinations).
Interday precisionIntraday precision
MOXTAMOXTA
Conc.Mean conc. ±SD% RSDConc.Mean conc. ±SD% RSDConc.Mean conc. ±SD% RSDConc.Mean conc. ±SD% RSD
UV [Abs]63.1±0.010.4830.1±0.0010.960.5±0.0020.4830.16±0.0021.53
243±0.481.06120.5±0.30.51243.1±0.0331.06120.585±0.050.85
423.1±0.010.54211±0.0050.51423.2±0.010.54211.0±0.0181.79
HPLC [Area]235283±4.30.01126514±3.050.01235573±3.510.03126509±20.007
692611±2.080.02379246±2.510.03692606±2.510.03379241±2.640.003
12183942±2.30.016155324±5.290.0512183944±40.056155320±2.080.001
HPTLC [Vol]894.8±0.030.034487.1±5.521.13895.6±0.540.574487.4±1.260.25
12107±0.060.056559±0.800.1412108.6±1.161.076558±0.560.1
20132±0.030.069684±1.230.1820132±0.860.869683±0.040.23

Repeatability

Repeatability is an exactness of measurements made under the same circumstances in a brief period of time usually over several injections on various days.

To assess repeatability, a standard solution containing a mixture of drugs was injected six times. The % RSD (Relative Standard Deviation) of the resulting peak areas was then calculated to evaluate the consistency of the results.

Accuracy

The accuracy of the method was evaluated by calculating the recovery of MOX and TA using the standard addition method at three different concentration levels (80%, 100%, and 120%) relative to a pre-analyzed marketed sample. For UV-visible spectrophotometry, known amounts of standard solutions were prepared with concentrations of 12 µg/mL for MOX and 6 µg/mL for TA. For RP-HPLC, standard solutions containing 8 µg/mL of MOX and 4 µg/mL of TA were added to the pre-analyzed sample solution. In HPTLC, known quantities of standard solutions were applied to spots on the pre-analyzed sample solution, which contained 20 µg/µL of MOX and TA.

Detection Limit and Quantification Limit

The Detection Limit and the Quantitation Limit of drug were determined by calculating the Signal-to-Noise ratio (S/N), with a value of 3.3 for DL and 10 for QL, as per the guidelines set by the International Conference on Harmonization (ICH). DL and QL were calculated using below formula.

Where, σ = standard deviation of the response,

S = slope of the calibration curve.

Robustness

The robustness of the methods was evaluated with deliberate variations in the method parameters. The changes in the responses of MOX and TA were observed as follows: For UV-visible spectrophotometry, the instrument was altered; for RP-HPLC, the flow rate was varied by ±1 mL/min; and for HPTLC, the mobile phase composition was modified by ±1 mL. Table 5 shows the robustness results for UV, RP-HPLC and HPTLC study of MOX and TA.

Table 4: Recovery study (Average of three determinations).
MethodConc. of added drug% Recovery% RSD
MOXTAMOXTA
UV80%98.23%98.6%0.41.1
100%98.53%101.6%0.21.1
120%101.3%100.6%1.50.5
HPLC80%100%100%0.060.2
100%99.56%99.45%0.050.4
120%99.99%98.99%0.090.6
HPTLC80%101%99.99%0.50.5
100%100%101.4%0.80.3
120%100.5%100%0.60.4
Table 5: Robustness results for UV, RP-HPLC and HPTLC Method.
DrugUVRP-HPLCHPTLC
Change of instrument (UV 1800)Change of instrument (UV 1900)Change Flow rate (0.9 mL/min)Change in Flow rate (1.1 mL/min)Change in Mobile PhaseChange in Mobile Phase
MOXSD%RSDSD%RSDSD%RSDSD%RSDSD%RSDSD%RSD
0.0120.440.0120.442.0810.0022.940.0031.3891.381.321.2
TA0.040.860.081.632.5160.0033.290.0044.230.81.20.2

CONCLUSION

The validated methods demonstrated reliability and reproducibility for the simultaneous estimation of MOX and TA in veterinary formulations, making them suitable for routine quality control analysis.

To estimate moxifloxacin and tolfenamic acid simultaneously in bulk and veterinary-marketed tablet formulations, this study involved the development and validation of UV-Vis, HPLC, and HPTLC methods. In accordance with the ICH Q2(R1) guidelines, the method was validated for accuracy, linearity, repeatability, intraday precision, interday precision, LOD, and LOQ.. The above findings imply that the proposed UV, RP-HPLC, and HPTLC methods can be applied to routine analysis of tolfenamic acid and moxifloxacin tablets.

REFERENCES

As published

Showing references and in-text citations exactly as published.

  1. 1.Ahmed, S. A.; Mukade, P. M.. Development and validation of a stability-indicating RP-HPLC method for simultaneous quantification of tolfenamic acid and moxifloxacin in pharmaceutical formulations. Journal of Pharma Insight and Research. n.d..GOOGLE SCHOLAR
  2. 2.Ahmed, S.; Mustaan, N.; Sheraz, M. A.; Nabi, S. A.; Ahmad, I.. Validation of a UV spectrometric method for the assay of tolfenamic acid in organic solvents. Journal of Pharmaceutics. 2015;2015:216249. https://doi.org/10.1155/2015/216249DOIGOOGLE SCHOLAR
  3. 3.Feldman, D.; Leahy, E.; Lee, S.-H.. Chemo preventive properties of tolfenamic acid: A mechanistic review. Current Medicinal Chemistry. 2018;25:1598–1608.GOOGLE SCHOLAR
  4. 4.Gul, S.; Khalid, F.; Khan, M. N.; Alam, M. T.. UV spectrophotometric method for estimation of moxifloxacin HCl in tablet dosage form and comparative study of its different brands. RADS Journal of Pharmacy and Pharmaceutical Sciences. 2015;3(2):41–49.GOOGLE SCHOLAR
  5. 5.International Conference on Harmonization (ICH).. ICH harmonised tripartite guideline: Validation of analytical procedures:. Text and methodology. 2005;Q2(R1).GOOGLE SCHOLAR
  6. 6.Kankaanranta, H.. Comparison of in vitro effects of fluixin and tolfenamic acid on human leukocyte and platelet functions. Inflammation. 1993;17:417–425.GOOGLE SCHOLAR
  7. 7.Kazi, S. H.; Sheraz, M. A.; Musharraf, S. G.; Ahmed, S.; Bano, R.; Haq, F. U. et al. Analysis of tolfenamic acid using a simple, rapid, and stability-indicating validated HPLC method. Antiinflammatory & Antiallergy Agents in Medicinal Chemistry. 2024;23(1):52–70. https://doi.org/10.2174/1871523022666230608094152DOIGOOGLE SCHOLAR
  8. 8.Khalifa, H. O.; Shikoray, L.. Veterinary drug residues in the food chain as an emerging public health threat: Sources, analytical methods, health impacts, and preventive measures. Foods. 2024;13(11):1629. https://doi.org/10.3390/foods13111629DOIGOOGLE SCHOLAR
  9. 9.Mali, A. N.; Badgujar, V. L.; Bhadane, H. Y.. Analytical method development and validation of moxifloxacin and tolfenamic acid in bulk drug and pharmaceutical dosage form by RP-HPLC method. Volume. 2025;24(Issue 06).GOOGLE SCHOLAR
  10. 10.Meena, M.; Prajapat, A.; Deori, N.; Gurjar, T.; Patel, P.; Saini, S.. Moxifloxacin and its therapeutic uses in animals: An overview. Journal of Entomology and Zoology Studies. 2019;7(4):929–934.GOOGLE SCHOLAR
  11. 11.National Center for Biotechnology Information.. PubChem Compound Summary for CID 152946, Moxifloxacin. 2025.GOOGLE SCHOLAR
  12. 12.Shende, K. V.; Dewani, A. P.; Bawne, Y. B.; Chachda, N. O.. Development and validation for HPLC method of estimation of moxifloxacin in eye drop formulation. International Journal of Research and Technology Innovations. 2022;7(11).).GOOGLE SCHOLAR
  13. 13.Tarkase, K. N.; Admane, S. S.; Sonkhede, N. G.; Shejwal, S. R.. Development and validation of UV-spectrophotometric methods for determination of moxifloxacin HCL in bulk and pharmaceutical formulations. Der Pharma Chemica. 2012;4(3):1180–1185.GOOGLE SCHOLAR

Cite this article

SELECT FORMAT

Gosavi, S. A., Bornare, P. D., Tangde, J. B., & Kulkarni, A. S. (2026). Simultaneous Estimation of Moxifloxacin and Tolfenamic Acid: Development and Validation of UV-visible, HPLC, and HPTLC Methods. International Journal of Pharmaceutical Investigation, 16(4), 1451–1456. https://doi.org/10.5530/ijpi.20260122