Article

Integration of Green Chemistry Approach for Development of Box-Behnken Design Assisted RP-HPLC Method for Estimation of Nepafenac in Ophthalmic Dosage Form: A QbD Supported Degradation Approach

Divya Ratnakumar Patil1, Mahesh Palled1★, Shailendra Sanjay Suryawanshi1, Priya Prakash Shetti3, Vrushali Patil1, Tanay Bhingurde1, Simran Gawas2, Ronak Dsouza1, Sairaj Bhogan1, Rakshita Hirakal1, Siddhesh Bandekar1, Vittal Gavali1★ Corresponding author

  1. 1Department of Pharmaceutical Analysis, K KLE College Pharmacy, Belagavi, KLE Academy of Higher Education and Research, Belagavi, Karnataka, INDIA.
  2. 2Department of Pharmaceutical Quality Assurance, KLE College Pharmacy, Belagavi, KLE Academy of Higher Education and Research, Belagavi, Karnataka, INDIA.
  3. 3Dr. Prabhakar Kore Basic Science Research Center, KLE Academy of Higher Education and Research, Belagavi, Karnataka, INDIA.

CORRESPONDENCE

Mahesh Palled

Dr. Mahesh Shivbasappa Palled Department of Pharmaceutical Analysis, KLE College of Pharmacy, Belagavi, KLE Academy of Higher Education and Research, Belagavi, Karnataka, INDIA.

mspalled@klepharm.edu

Received: 01-11-2025; Revised: 17-03-2026; Accepted: 27-05-2026.

Volume 16, Issue 4 · pp. 1578–1592 · PUBLISHED Oct-Dec 2026 · DOI: 10.5530/ijpi.20260266

View on IJPI original site ↗

ABSTRACT

Background NSAIDs, or Non-Steroidal Anti-Inflammatory medicines, are a large family of chemically diverse medications with a wide range of effects. Nepafenac is an anti-inflammatory medication that is used topically as an aqueous solution. Objectives To develop a simple, dependable, and eco-friendly Reverse-Phase High-Performance Liquid Chromatographic (RP-HPLC) approach for the quantitative measurement of nepafenac in ophthalmic solutions using a Quality by Design (QbD) methodology. Materials and Methods A Box-Behnken experimental design was used to refine the process and identify the variables influencing chromatographic performance. Chromatographic separation was achieved on a Shimadzu C18 column (250 x 4.6 mm i.d., 5 µm) using a mobile phase of methanol:0.1% orthophosphoric acid in water (75:25 v/v), adjusted to pH 3.0, at a flow rate of 1.1 mL/min and detection at 236 nm. Results Nepafenac was eluted with a retention time of 4.018 min and showed great accuracy, with recovery ranging from 98.2% to 101.9%. The test for the commercial ophthalmic formulation produced a 96.16% result. Studies on forced deterioration in acidic, alkaline, oxidative, thermal, and photolytic environments validated the method’s stability-indicating properties. Furthermore, the eco-friendliness of the created method was confirmed by evaluating its environmental sustainability using AGREE and the GAPI greenness assessment method. Conclusion The appropriateness of the suggested method for regular quality control analysis of Nepafenac in ocular dosage forms was demonstrated through its validation in compliance with International Council for Harmonisation (ICH Q2(R2)) criteria.

KEYWORDS

0% READ

FULL TEXT

INTRODUCTION

NSAIDs, or non-steroidal anti-inflammatory medicines, are a large family of chemically diverse medications with a wide range of effects (Ashour et al., 2024). Nepafenac (Figure 1) is an anti-inflammatory medication that is used topically as an aqueous solution. During cataract surgery, it lessens discomfort, manages inflammation, and enhances patient comfort (Zokande et al., 2025). Nepafenac is a prodrug of Amfenac. It is used in an ocular solution formulation to alleviate pain and inflammation (Padhye et al., 2022). In chemical terms, nepafenac is a [2-(2-amino-3-benzoylphenyl)acetamide] (Gupta et al., 2024). The US Food and Drug Administration (FDA) has authorised nepafenac ophthalmic suspension, 0.1%, a novel topical NSAID prodrug, to relieve pain and inflammation following cataract surgery (Lindstrom et al., 2006). The production of certain proinflammatory mediators, such as prostaglandins, which have been connected to the breakdown of the blood-aqueous barrier and the rise in vascular permeability alterations linked to inflammation and edema, is prevented by the suppression of COX enzyme activity (Akbas et al., 2025).

Figure 1: Chemical structure of Nepafenac.

A pharmaceutical quality management approach called Quality by Design (QbD) anticipates, manages, and methodically addresses potential hazards during the research and production phases. In order to ensure product quality, Quality by Design (QbD) urges the pharmaceutical sector to apply science-based manufacturing concepts and risk management to obtain process and product expertise (Lee et al., 2022). Analytical evaluation is a crucial method for pharmaceutical product quality control. Inaccurate readings and data that might be dangerous for the medicine and product development stage could result from a faulty analytical assessment. Several pharmaceutical medication regulatory organisations, including the "US Food and Drug Administration" and the " International Council for Harmonisation" (ICH), have established Quality by Design (QbD) techniques and guidelines to address these important challenges and concerns (Suryawanshi et al., 2022). The Food and Drug Administration (FDA) and the International Conference on Harmonisation (ICH) are actively promoting QbD in an effort to reduce growing development costs and regulatory obstacles to innovation and inventiveness (Mishra et al., 2018). Understanding dependent variables, different factors, and their interaction effects through a desired set of experiments on the answers to be studied is a crucial part of the QbD (Patel et al., 2021). The Quality by Design (QbD) idea states that during pharmaceutical or analytical development, quality should be included in the product or process. The quality of processes and products can typically be affected by a variety of input elements. In order to comprehend the impact of multidimensional input factors and their interactions on the output responses of pharmaceutical goods and analytical techniques, Design of Experiments (DoE) has become a popular tool in recent years (Fukuda et al., 2018).

The goal of Green Analytical Chemistry (GAC) is to lessen the negative impacts that analytical operations have on the environment, human health, and safety (Yin et al., 2024). Green chemistry gave rise to Green Analytical Chemistry (GAC) in 2000. Chemists are quite interested in this relatively new branch of green chemistry, which focuses on how analytical chemists may help make laboratory procedures more ecologically friendly (Gałuszka et al., 2013). Analytical chemistry plays two separate and conflicting roles in green chemistry. It protects the environment by assessing the effects of chemical activities, but it also has the potential to exacerbate environmental issues because of the large amounts of hazardous materials used or produced during an analytical process and the high energy consumption. By addressing worker safety, energy efficiency, hazardous laboratory waste production, and solvent/reagent safety, GAC sought to redefine and review analytical processes (López-Lorente et al., 2022).

Literature review revealed that there are very few chromatographic techniques for nepafenac estimation. Out-of-Trend (OOT) or Out-of-Specification (OOS) results are a common consequence of reported methods' reliance on expensive or dangerous solvents, complex processes, complex solvent systems, lack of robustness, frequent failures and long retention time. The Quality by Design (QbD) methodology has not been used in the development of nepafenac analytical procedures till date; many do not satisfy current regulatory requirements, and the main objectives of the proposed research work is to develop and optimise a simple, easy, robust, accurate RP-HPLC method by the QbD approach.

MATERIALS AND METHODS

Materials

Chemicals: Nepafenac gift sample was obtained from Deccan Nutraceuticals Pvt. Ltd., Pune, HPLC-grade methanol, 0.1N HCl, 0.1N NaOH, and 3% hydrogen peroxide were obtained from the KLE College of Pharmacy store, Belagavi; orthophosphoric acid and milli-Q water were provided by Dr. Prabhakar Kore Basic Science Research Center, Belagavi, and every chemical employed in this investigation was of analytical grade.

Instrument

In the proposed research work HPLC used was Shimadzu Sil-20ACHT, and the Shimadzu Lab Solutions software was used. And Milli-Q water collected from Thermo Scientific Smart2Pure Pro, the powdered sample of Nepafenac and the standard were weighed using a Wensar AN ISO 9001 weighing balance. In order to Brason 1800 ultrasonic cleaner sonicator was used to both degas the solvent system and dissolve the drug, and to dissolve the ophthalmic drug in the solvent.

Chromatographic conditions

The chromatographic separation of Nepafenac was achieved on a Shimadzu C18 column (250 X 4.6 mm i.d, 5 µm). A solvent system composed of methanol: 0.1% orthophosphoric acid in water proportion of 75:25v/v (pH 3.0), confirmed by QbD trial runs. The retention time of Nepafenac was obtained at 4.018 min with UV identification at 236 nm. The temperature of the column is 34.5ºC with a flow rate of 1.1 mL/min. The injection volume was 10 µg/mL. For the mobile phase, 0.4 mL of orthophosphoric acid in 400 mL milli-Q water was used. It is sonicated, filtered through a 0.45 µm membrane filter (Nylon), and degassed before preparation of the solvent composition.

Preliminary analysis of drug

The colour of Nepafenac compared with the reported characteristics mentioned in the COA, and Nepafenac is fully soluble in methanol and partially soluble in water.

Preparation of solvent system

0.4 mL of orthophosphoric acid was measured and transferred to 400 mL of Milli-Q water, and it was sonicated for 10 min, and after filtering through a 0.45 µm membrane filter, degassing was carried out, and the mobile phase used was methanol:0.1% orthophosphoric acid in water with the ratio 75:25 (v/v).

Preparation of standard stock solution

The Nepafenac stock solution was made by dissolving 10mg of Nepafenac in 10 mL of methanol, and this stock was sonicated to solubilise the Nepafenac. From this stock, 1 mL of solution was pipette out and transferred into a 10 mL volumetric flask, and it was diluted using methanol. This stock was used for method development and validation parameters. Additionally, the mentioned secondary dilution and the use of methanol as a diluent yield additional workable solutions.

Preparation of sample solution

Accurately pipette out 1 mL from 0.1% ophthalmic suspension into a 10 mL volumetric flask, and volume was made up using methanol. After 5 min to solubilise it, from this 1 mL solution was pipette out and transferred to a 10 mL volumetric flask to get a 10 µg/mL solution, and volume was made up using methanol.

Selection of wavelength

From the standard stock solution, solutions were taken, and methanol was used for dilution and scanned over a range from 800-200 nm in UV spectrophotometry, and it was observed that the drug showed absorbance at 236 nm.

Preliminary method development

In order to select the proper stationary phase, preliminary experimental runs were carried out to find possible combinations and select the column and solvent system. For the initial trials, a review of the literature was done. Methanol was chosen as a cost-effective solution. Additionally, an aqueous solvent with varying orthophosphoric acid concentrations was chosen. Additional experimental research was conducted using the C18 stationary phase.

Method optimisation based on QbD principles

QbD is described as “a systematic approach to development that starts with predetermined objectives and emphasises product and process understanding based on sound science and quality risk management.” The QbD approach includes developing tests and controls based on the scientific limits of understanding during the development stage, utilising the knowledge and data generated during the product's life cycle to work on continuous improvement, and improving scientific understanding of critical parameters and qualities of the product. We have worked on several QbD components and applied them to the practical methods in this inquiry. It began with the determination of the Analytical Target Profile (ATP), then used the fishbone approach to analyse the Critical Quality Attributes (CQAs) and Risk Assessment (RA). The implementation of DOE, which aids in factor screening and RP-HPLC process optimisation, is the primary focus of the further approach (Suryawanshi et al., 2022).

Analytical target profile

The first and most crucial stage in developing a QbD-based analytical technique is identifying and setting up the ATP, which is defined as gathering the data needed to create the desired quality profile. This aids in guaranteeing the analytical process's quality, safety, and practical use at the location of its commercial application in the pharmaceutical sector. The "target drug, target samples and method application, analytical method, instrument characteristics and requirements, sample preparation steps, and analytical procedure quality attributes" are some of the components that make up ATP (Park et al., 2022).

Critical Quality Attributes (CQAs)

The selection of different CQAs is a crucial and crucial phase in the creation of a QbD-based method in order to satisfy the requirements of the target profile of the analytical procedure. "The measurable parameters of the chromatogram of analyte that should be within an appropriate and acceptable limit to warrant the desired quality and ability of the analytical procedure" is how the CQAs are defined.

The Tailing Factor (TF), Retention Time (RT), Peak Area (PA), Theoretical Plates (TP), assay limit, etc., are typically considered key quality attributes in chromatographic development. RT, TP, and TF are the characteristics that actually affect how well an analytical process works (Suryawanshi et al., 2022).

Risk Assessment

Risk assessment is also a crucial element in the development of QbD-based procedures. Risk assessment was used in this investigation to assess the likelihood of procedure failures. An "Ishikawa Fish-Bone" (IFB) diagram was created to carry out a cause-and-effect model for the relationship of "critical material attributes" and "critical method parameters" with the Critical Analytical characteristics (CAAs) (Gaudin et al., 2016).

Factor Screening by Experiment Avenue Design with Box-Behnken Design (BBD)

Design Expert software was used to optimise a new chromatographic process for Nepafenac. This software used the Box-Behnken design to optimise the "Critical Process Parameters" (CPPs) or "Critical Method Parameters" (CMPs) and evaluate how these parameters interacted with the CQAs. BBD requires fewer experimental runs because it is a three-factor, two-level design.

Box-Behnken Study Design for Optimisation

Three factors and two levels of BBD were used in the chromatographic optimisation of parameters to assess the primary impacts and quadratic effects of crucial factors on the variables of identified responses. The following procedures are part of the screening phase of the BBD, which consists of 17 experiment runs. The flow rate, organic phase (% methanol), and detection wavelength were all chosen during the initial step of CMP selection. The selection of CQAs is part of the study's second phase. The CQAs used for this investigation are RT, PA, TP, and TF.

Throughout the practical experiments, these reactions were seen (Suryawanshi et al., 2022).

Development of Methods Based on Experimental Design

As per the factor screening method, the selection of the CMPs which are affecting the performance of the procedure was optimised employing 3 factors at two equidistant levels (low (-1) and high (+1) levels). A 10 μg/mL of Nepafenac was used for all chromatographic runs, and analysed for CQAs (RT, PA, TP, and TF) (Beg et al., 2012).

Data Analysis and validation of methods

Completing the proposed trial, the responses were added to the software, and other graphs, such as “graph plots” and “3D response surface plots” were attained. These charts indicate how CMPs affect the chosen CQAs. The evaluation of these plots was used to determine which parameter produced the most logical answers. These data were used to determine the procedure’s final CMPs and choose the ideal conditions. For each answer, a statistical instrument such as “Analysis of Variance” (ANOVA) was employed to determine he significance of each research parameter using the p-value.

Method validation

Method validation was done in accordance with ICH principles. The quality assessment of Nepafenac in its marketed formulation was then successfully conducted using the suggested RP-HPLC approach.

System suitability

“A crucial component of any analytical approach is system and testing appropriateness”. replicates of a 10 μg/mL standard Nepafenac solution were injected, and each chromatogram was then assessed based on its RT, TP, and TF (Shivabasappa et al., 2019).

Specificity and selectivity

The HPLC peak of the Nepafenac solution (10 μg/mL) and blank chromatogram of the solvent system were obtained in order to determine the procedure's specificity and selectivity. It aids in determining the peak purity, analyte, and interference from other peaks (Bhanusali et al., 2022).

Linearity and range

The procedure linearity was evaluated between 2 and 10 µg/mL of Nepafenac, by preparing various concentrations, the linearity response was determined and injecting sample was injected three times into HPLC, recording chromatograms and noting the peak area of each graph. The peak area of the standard calibration curve was plotted against the Nepafenac concentration in μg/mL (Shivabasappa et al., 2019).

Detection and Quantification Limit

The lowest concentration of analyte in a sample that can be identified but may not always be quantified as an exact number is known as the detection limit of a particular analytical technique. The lowest amount of analyte in a sample that can be quantitatively identified with appropriate precision and accuracy is known as the quantitation limit of a particular analytical process”. A parameter of quantitative assays for low concentrations of chemicals in sample matrices, the quantitation limit is especially useful for identifying contaminants and/or degradation products (Sanjay et al., 2019).

where “σ” is the standard deviation of the regression line’s Y-intercept and “S” is the slope of the calibration curve.

Precision

The Relative Standard Deviation (RSD) is used to estimate the precision. Three replicate injections at concentrations of 2,6,10 µg/mL were used to estimate the precision. Three replicates of Nepafenac concentrations were injected for the intraday and interday precision investigation, and the percentage RSD was calculated (It was evaluated on three separate days in addition to the same day) (Shivabasappa et al., 2019).

Robustness

The method’s robustness was assessed by analysing distinct wavelengths (i.e., 236±0.2) and mobile phase (75:25±0.5). The corresponding absorbances were recorded, and the percentage RSD was used to show the outcome (Shetti et al., 2021).

Ruggedness

The method's ruggedness was assessed by having two distinct analysts perform the analysis and record the corresponding absorbances. % RSD was used to represent the outcome (Shetti et al., 2022).

Accuracy

The method’s accuracy was assessed by creating solutions with varying concentrations (80%, 100%, 120% respectively) and the amount of pure drug varied (8 µg/mL, 10 µg/mL, 12 µg/mL for 80%, 100%, 120% respectively) and amount of marketed formulation remain constant (10 µg/mL). The accuracy was shown by the percentage of recovery when solutions were produced in triplicate (Akula et al., 2021).

Assay

To perform the analysis of the pharmaceutical dosage form containing Nepafenac, a suspension comprising an equivalent amount of 10 mg of the drug was transferred to a 10 mL volumetric flask. After adding methanol to achieve the necessary volume, the mixture was sonicated for three minutes. Next, 1 mL of this solution was measured, transferred to a 10 mL volumetric flask, and the volume was adjusted using methanol. Similarly, 1 mL of the produced solution was measured, transferred to a 10 mL volumetric flask, and the volume was adjusted using methanol. For the subsequent chromatographic analysis, 10 µL of the solution was injected into the system, and the assay's percentage was calculated (Patel et al., 2024).

Forced degradation study

For the forced degradation investigations of Nepafenac, a number of degradation conditions were employed, including hydrolysis, oxidation, photolysis (UV light), and thermal degradation (Patel et al., 2024). 10 mL volumetric flasks were filled with precisely weighed 10 mg of Nepafenac and made up to volume using methanol. From the above solution, 1 mL was measured and transferred to a 10 mL volumetric flask (100 µg/mL), which was used as a stock solution to investigate the effects of forced deterioration.

Acid degradation

A 10 mL volumetric flask was filled with 1 mL of a 100 µg/mL Nepafenac standard stock solution, followed by 1 mL of 0.1N HCl. This flask was left at room temperature for 3 hr. The mixture was then neutralised, and the process was stopped by adding 1 mL of newly made 0.1N NaOH. A liquid chromatography apparatus was used to analyse the resultant solution after it had been diluted with mobile phase up to 10 mL.

Base degradation

Similarly, a 10 mL volumetric flask was filled with 1 mL of a 100 µg/mL Nepafenac standard stock solution to conduct the base degradation experiment. 1 mL of 0.1N NaOH was then added. To allow for base degradation, the flask was left at room temperature for 3 hr. 1 mL of 0.1N HCl was injected to finish the neutralisation process after the allotted time. A liquid chromatographic apparatus was used to analyse the base-degraded sample after it had been diluted with mobile phase to a final volume of 10 mL.

Oxidation degradation

A 10 mL volumetric flask was filled with 1 mL of a 100 µg/mL Nepafenac standard stock solution to conduct the oxidation degradation experiment. 1 mL of H2O2 was added, the flask was left for 2 hr at room temperature, and the solution was injected into a liquid chromatographic system after being diluted to 10 mL with the mobile phase.

Photodegradation

A sunlight source was used to expose 10 mg of Nepafenac powder in a petri dish for 4 hr in order to measure photolytic degradation. For the tests that followed, the resultant solution, which had a concentration of 10 μg/mL, was used. The solution was put into a liquid chromatography apparatus for examination following photodegradation.

Thermal degradation

For thermal degradation, 10 mg of Nepafenac powder was weighed, put in a petri dish, and heated to 70ºC for 3 hr in a hot air oven. A 10 μg/mL concentration was prepared for the tests using the resultant solution, which was subjected to thermal stress for the designated amount of time. The liquid chromatography apparatus was then filled with the thermal degradation solution (Patel et al., 2024).

Greenness assessment

Since several factors need to be taken into account, determining the best method for evaluating an analytical procedure's green nature is difficult. One, it is widely acknowledged that in order to declare a method or product to be sustainable, concrete evidence of actual environmental consequences must be provided. Here, the created instruments for evaluating how environmentally friendly the specified analytical processes are come to the rescue (Płotka-Wasylka et al., 2021).

AGREE® Tool

AGREE is a straightforward and all-inclusive instrument that evaluates the environmental friendliness of analytical tests and yields answers that are clear and easy to understand. The 12 GAC principles are converted into a 0-1 scale in order to calculate the AGREE metric. Assessing the solvents' toxicity, the energy used, and the trash generated during the testing generates a net score. Based on energy consumption, all other activities receive good marks and while waste of any form receives a bad score (Rabadiya et al., 2025).

Green Analytical Procedure Index (GAPI)

The five pentagrams of the GAPI pictogram can be used to assess and disclose the greenness of various stages of the full analytical test. The GAPI pictogram uses a colour scale with three levels (green, yellow, and red hues imply low, medium, and high impact of the analytical process on the environment and human health, respectively) to show the greenness of various stages of the overall analytical method (Yin et al., 2024).

RESULTS AND DISCUSSION

Preliminary analysis of the drug

Nepafenac has a yellowish colour, a solid state. A solubility test revealed that nepafenac is only marginally soluble in water and totally soluble in methanol.

Method development

Preliminary experiments based on literature search and trial and error were conducted in order to optimise a straightforward, economical, precise, and accurate approach for assessment and quality control of the Nepafenac in its bulk as well as pharmaceutical ophthalmic dosage form. Initially, other combinations of solvents, including methanol and o-phosphoric acid, were used to determine the mobile phase. To improve the Nepafenac separation, the buffer and methanol were tested in various concentrations. The choice of orthophosphoric acid at 0.1% concentration, shown in the first runs to result in quicker and more efficient drug separation with elution of Nepafenac at lower RT, along with low peak tailing and satisfactory peak symmetry.

Analytical Quality by design approach and its application

The proposed RP-HPLC method, which is included in the methods section, was subjected to a number of QbD techniques and approaches. Table 1 presents the ATP, CQAs, and process parameters of the method that were examined, determined, and identified.

Table 1: QTPP, CQAs and CMPs of proposed RP-HPLC Method.
Sl. No.QbD ElementDescription
1Quality Target Product Profile (QTPP)Flow rate, mobile phase composition, detection. Wavelength, pH, column temperature, injection. Volume, system pressure and buffer characteristics.
2Critical Quality Attributes (CQAs)Retention time, peak area, and theoretical plate. Count, purity and tailing factor
3Critical Method Parameters (CMPs)Specificity, selectivity, linearity, precision. Accuracy, robustness, ruggedness, Limit of Detection (LOD) and limit of quantification.

Risk Assessment Screening Studies

Risk assessment research was conducted to examine the CMPs, which are high-risk variables that significantly impact the CAAs. The IFB diagram (Figure 2) was created for this investigation in order to identify significant risk variables that might affect the method's effectiveness. The elements that increase risk mentioned may include instrument-related factors like injection volume, flow rate, chromatographic mode, Temperature, and solvent system ratio. By using an appropriate experimental optimisation strategy, the high-risk procedure variables were identified and subjected to further investigation. The mobile phase, flow rate, the percentage of organic phase (methanol) in the mobile phase, and the column temperature were chosen as the high-risk technique factors.

Figure 2: Ishikawa Fishbone diagram.

Design of Box-Behnken Optimisation

In order to identify the primary, interactional, and quadratic impacts of these parameters on RT, PA, TP, and TF, BBD optimised them. After the 17 runs were completed, software was used to statistically evaluate the findings. RT, PA, TP, and TF were chosen as the dependent responses, whereas flow rate of mobile phase, percentage of organic phase in mobile phase, and column temperature were chosen as the independent factors. Table 2 displays the BBD optimisation, along Table 3 shows the confirmation location after 17 runs. The program performed statistical optimisation and Analysis of Variance (ANOVA). Table 4 displays the results of the ANOVA. This suggests the validity of the model.

Table 2: Box-Behnken Design for Optimization.
Factor 1Factor 2Factor 3Response 1Response 2Response 3Response 4
StdRunA: OPB: FRC: TPRTareaTFNTP
%mL/minoC
151751.134.54.0185502041.2332515
112750.9374.8526685381.2354097
173751.134.54.0185502041.2393177
104751.3323.4544698551.2243099
65801.1323.8626496441.2415061
146751.134.54.0155507231.2333035
87801.1374.2136730151.2317046
18700.934.55.3756590261.2488922
79701.1374.2365457821.2497810
410801.334.53.4687078871.2254047
1311751.134.54.0115508501.2333925
512701.1323.6575431091.275935
913750.9324.8046798941.3557992
314701.334.54.1384665411.2132144
215800.934.54.2877091651.2478231
1616751.134.54.0135548441.2152106
1217751.3373.5024687231.2154068
Table 3: Confirmation location after 17 runs.
A: OPB:FRC:TP
%mL/minoC
751.134.5
Table 4: Results from statistical analysis
ANOVA ParameterRTPeak AreaTPTF
R-Square0.85540.94310.84380.7658
Adjusted R-square0.66960.870.6430.4739
Predicted R-square-1.31270.0922-1.1733-2.6687
Standard Deviation0.29530365.361375.430.0203
% C.V7.175.1628.11.63
F-value4.612.94.24.14
P-value0.02830.02830.03580.0289

The "3D-surface plots were also examined to establish design space and show how independent parameters affected the corresponding response variables. One element was maintained constant for every plot because the suggested model had more than two independent factors. The 3D surface plot map in Figure 3 illustrates how flow rate, organic phase composition percentage, and wavelength affect RT, PA, TP, and TF.

Figure 3: shows how the flow rate and % of organic phase (A), Flow rate and temperature (B), and % of organic phase and temperature (C), Impact the retention time in 3D surface plots. Peak area is also influenced by the % of organic phase and flow rate (D), the % of organic phase and temperature (E), and the flow rate and temperature (F) Additionally, the tailing factor is affected by 3D surface plots showing the % of organic phase and flow rate (G), the % of organic phase and temperature (H), and the flow rate and temperature (I), also % of organic phase and flow rate (J), % of organic phase and temperature (K), Flow rate and temperature (L), Affect the theoretical plates.

Method development

Figure 4 displayed the typical Nepafenac HPLC chromatogram with an RT of 4.018 min.

Figure 4: Chromatogram depicting the method development peak.

Method validation

System testing parameters, including RT, TP, and TF, were assessed, and %RSD was calculated before the analysis.

System suitability

After injecting 6 replicates of a standard Nepafenac solution containing 10 μg/mL, each chromatogram was evaluated using its Area. Table 5 shows system suitability data and % RSD.

Table 5: System suitability study data.
Concentration 10 μg/mLRetention TimePeak AreaTailing FactorTheoretical Plates
Mean4.0394787151.2344471
SD0.0047277.330.00615.95
%RSD0.1121.520.5450.356

Specificity and selectivity

The specificity and selectivity of the procedure were assessed by obtaining the HPLC peak of the Nepafenac solution (10 μg/mL) and the blank chromatogram of the solvent system. Figures 5 and 6 show the blank and standard peak.

Figure 5: Chromatogram displays the blank.
Figure 6: Chromatogram displays a standard peak.

Linearity and Range

By producing different concentrations of Nepafenac, the linearity response was ascertained, and the procedure's linearity was assessed between 2 and 10 µg/mL. Figure 7 displays a plot of the peak area of the standard calibration curve against the concentration of Nepafenac in μg/mL, and R2 was found to be 0.998.

Figure 7: Displays overlay peaks and Calibration Curve of Nepafenac.

Detection and Quantification Limit

The LOD and LOQ values were obtained as 0.284 and 1.93, respectively, by using these formulas:

LOQ is 10 × σ/S and LOD is 3 × σ/S

Precision

For intraday and interday precision, three replicates of nepafenac concentrations were injected, and % RSD was falls within acceptable range, and the precision data is displayed in Table 6.

Table 6: Intraday and interday precision data assay of Nepafenac.
PrecisionIntradayInterday1Interday2Interday3
Conc.Peak area% RSDPeak areaRSDPeak areaRSDPeak areaRSD
2 µg/mL1087900.1091083880.1571088010.4841093660.153
6 µg/mL3124250.8623111240.3063192060.1643159570.991
10 µg/mL4741330.1844744700.3064727050.3174758170.526

Robustness

The robustness parameter was determined by doing the study at various wavelengths (i.e., 236±0.2) and Mobile phase (75:25 ±5) and the % RSD was falls within acceptable range. Robustness data is displayed in Table 7.

Table 7: Robustness data of Nepafenac obtained by RP-HPLC.
Robustness
Peak Area
Change in wavelengthChange in Mobile phase
Conc.234 nm%RSD236 nm%RSD238 nm%RSD70:30%RSD75:25%RSD80:20%RSD
2 µg/mL1089550.6921089340.7271059210.33710008940.5341087200.1491192460.315
6 µg/ mL3105010.1153080070.1143010710.3353062340.1713108140.1253266250.313
10 µg/mL4777510.3264742890.2474636290.2954881420.3314736200.6024878900.521

Ruggedness

The ruggedness parameter was determined by doing study by two analysts, and % RSD was falls within acceptable range. Ruggedness data is displayed in Table 8.

Table 8: Ruggedness data of Nepafenac obtained by RP-HPLC.
Ruggedness
Change in Analyst
Conc.Analyst 1%RSDAnalyst 2%RSD
2 µg/mL1089440.6871091640.499
6 µg/mL3159940.9463111020.903
10 µg/mL4761630.5854727030.642

Accuracy

At 80%, 100%, and 120% of the sample concentration, accuracy was evaluated using the conventional spike technique, and % RSD falls within acceptable range. Table 9 displays the outcomes of preparing and injecting each level in triplicate.

Table 9: Accuracy study data of Nepafenac obtained by RP-HPLC
LevelSample conc. (µg/mL)Std. conc. (µg/mL)Total conc. (µg/mL)Mean of peak areaAmount RecoveryMean %%RSD
80%10 µg/mL8 µg/mL18 µg/mL84292417.6898.20%0.082
100%10 µg/mL10 µg/mL20 µg/mL95043019.9499.70%0.158
120%10 µg/mL12 µg/mL22 µg/mL106944822.42101.90%0.049

Assay

A suspension containing an equal quantity of 10 mg of drug was determined. A standard stock solution containing 1000 µg/mL of Nepafenac was prepared this stock solution was used to make various concentrations of solution, and peak areas were recorded for the Nepafenac estimation. and % assay was found to be 96.16% i.e., within the acceptable range, as displayed in Table 10. The nepafenac chromatogram at retention time 3.99 is displayed in Figure 8.

Figure 8: Chromatogram depicting Nepafenac sample peak.
Table 10: Assay data of Nepafenac.
DrugConc.An area found% RSD% Assay
Nepafenac10 µg/mL4574 4598740.22 0.2296. 96.16%

Degradation study

Heat, UV radiation, hydrogen peroxide, bases, and acids were among the stress conditions to which nepafenac was vulnerable; oxidative and acidic environments showed the most deterioration. Nepafenac broke down and changed into degradation products due to oxidation, acid hydrolysis, and base hydrolysis. Additionally, increased oxidative and base degradation took place. Table 11 presents study results on force deterioration.

Table 11: Degradation data of Nepafenac.
Type of DegradationStress conditionTimes (Hr)Area% Degradation
Acid degradation0.1 N HCl (Room temperature)3 hr43220710.33%
Base degradation0.1N NaOH (Room temperature)3 hr39756119.95%
Oxidation degradation3%H2O2 (Room temperature)2 hr40992716.33%
Photolytic degradationSun light4 hr4531435.23%
Thermal degradationWater bath 70°C3 hr42848811.29%

Greenness assessment

AGREE® Tool

according to the Figure 9 pictogram, the overall score in the center is 0.62, which is in the light green area and acceptable environmental performance of the evaluated method. The colour and score of each numbered segment represent the procedure’s performance of the evaluated method. The colour and score of each numbered segment represent the procedure’s performance across distinct GAC principles. Principles 2, 4, 5, and 10 all exhibit excellent performance with a score of 1.0, while principles 1(0.80) and 6(0.80) also exhibit high performance. Principles 3(0.66), 8(0.51) and 12(0.40) exhibit poor performance, indicating significant flaws.

Figure 9: AGREE score for the determination of Nepafenac.

GAPI Tool

By analysing the complete process, the GAPI pictogram (Figure 10) offers a comprehensive assessment of the environment in which an analytical procedure operates, which is summarised by the yellow-coloured centre pentagon. The five surrounding pentagons represent important phases of the analytical process. A yellow colour denotes modest environmental performance, red sectors show poor performance, and green sectors show criteria with good to exceptional performance.

Figure 10: GAPI score for the determination of Nepafenac.

CONCLUSION

A simple, robust, and eco-conscious RP-HPLC method for the quantitative estimation of Nepafenac in ophthalmic preparation was successfully developed using a Quality by Design (QbD) approach. Application of the Box-Behnken experimental design enabled systematic optimisation of critical method parameters, ensuring consistent chromatographic performance and enhanced method understanding. The optimised method provided good peak symmetry, short retention time, and efficient separation using a relatively simple mobile phase composition. Validation studies performed in accordance with ICH guidelines ICHQ2(R2) confirmed that the method demonstrated good specificity, precision, linearity, and accuracy, with recovery values ranging from 98.2% to 101.9%. The commercial ophthalmic formulation's assay yielded a result of 96.7%. Additionally, analyses of forced degradation under acidic, alkaline, oxidative, thermal, and photolytic stress conditions were conducted to assess the method’s capacity to indicate stability. In addition, the new method’s environmental sustainability was assessed using the AGREE and GAPI greenness evaluation methods, demonstrating its eco-friendliness through a limited environmental impact and reduced solvent use. Owing to its simplicity, reliability, reduced analysis time, and environmentally considerate solvent usage, the developed RP-HPLC method is well-suited for routine quality analysis of Nepafenac in ophthalmic dosage forms.

REFERENCES

As published

Showing references and in-text citations exactly as published.

  1. 1.Akbas, Y. B.; Aydin, F. O.; Kelebek, M.; Cakmak, S.; Ceylan, A.; Akbas, Z. S. et al. Comparison of topical nepafenac 0.1% and 0.3% on aqueous flare and macular thickness in patients with pseudoexfoliation following cataract surgery. Indian Journal of Ophthalmology. 2025;73(Suppl 3):S424–S427.GOOGLE SCHOLAR
  2. 2.Akula, G.; Sapavatu, S. N.; Jadi, R. K.; Battineni, J. K.; Boggula, N.. Analytical method development and validation for the estimation of tramadol in bulk and its formulations by UV-spectroscopy. Journal of Advanced Scientific Research. 2021;12(2):77–83.GOOGLE SCHOLAR
  3. 3.Ashour, H. K.; Korany, M. A.; Abdelhamid, A. G.; Belal, T. S.; Gawad, D. A.. Stability indicating multipurpose HPLC-DAD method for synchronic analysis of three non-steroidal anti-inflammatory drugs with a co-formulated preservative in ophthalmic dosage forms-Greenness/whiteness assessment. Microchemical Journal. 2024;199:110092.GOOGLE SCHOLAR
  4. 4.Beg, S.; Kohli, K.; Swain, S.; Hasnain, M. S.. Development and validation of RP-HPLC method for quantitation of amoxicillin trihydrate in bulk and pharmaceutical formulations using Box-Behnken experimental design. Journal of Liquid Chromatography and Related Technologies. 2012;35(3):393–406.GOOGLE SCHOLAR
  5. 5.Bhanusali, M.; Palled, M. S.; Suryawanshi, S. S.. Chromatographic estimation of cefetamet pivoxil in bulk and tablet dosage form: Development and validation approach. Int J Pharm Chem Anal. 2022;9(3):125–129.GOOGLE SCHOLAR
  6. 6.Fukuda, I. M.; Pinto, C. F. F.; Moreira, C. D. S.; Saviano, A. M.; Lourenço, F. R.. Design of experiments (DoE) applied to pharmaceutical and analytical quality by design (QbD). Brazilian journal of pharmaceutical sciences. 2018;54:e01006.GOOGLE SCHOLAR
  7. 7.Gałuszka, A.; Migaszewski, Z.; Namieśnik, J.. The 12 principles of green analytical chemistry and the SIGNIFICANCE mnemonic of green analytical practices. TrAC Trends in Analytical Chemistry. 2013;50:78–84.GOOGLE SCHOLAR
  8. 8.Gaudin, K.; Ferey, L.. Quality by design: a tool for separation method development in pharmaceutical laboratories. LCGC Supplements. 2016;29(10).).GOOGLE SCHOLAR
  9. 9.Gupta, P. K.; Pancholi, S. S.; Das, P.. In vitro drug release testing method for nepafenac ophthalmic suspension. Journal of Pharmaceutical Sciences. 2024;113(4):1061–1067.GOOGLE SCHOLAR
  10. 10.Lee, S. H.; Kim, J. K.; Jee, J. P.; Jang, D. J.; Park, Y. J.; Kim, J. E.. Quality by Design (QbD) application for the pharmaceutical development process. Journal of Pharmaceutical Investigation. 2022;52(6):649–682.GOOGLE SCHOLAR
  11. 11.Lindstrom, R.; Kim, T.. Ocular permeation and inhibition of retinal inflammation: an examination of data and expert opinion on the clinical utility of nepafenac. Current medical research and opinion. 2006;22(2):397–404.GOOGLE SCHOLAR
  12. 12.López-Lorente, Á. I.; Pena-Pereira, F.; Pedersen-Bjergaard, S.; Zuin, V. G.; Ozkan, S. A.; Psillakis, E.. The ten principles of green sample preparation. TrAC Trends in Analytical Chemistry. 2022;148:116530.GOOGLE SCHOLAR
  13. 13.Mishra, V.; Thakur, S.; Patil, A.; Shukla, A.. Quality by design (QbD) approaches in current pharmaceutical set-up. Expert opinion on drug delivery. 2018;15(8):737–758.GOOGLE SCHOLAR
  14. 14.Padhye, H.; Sonawane, B.; Munipalli, V. K.. Development and validation of HPTLC method for estimation of nepafenac in ophthalmic suspension. Int Res J Pharm Med Sci. 2022;5:17–23.GOOGLE SCHOLAR
  15. 15.Park, G.; Kim, M. K.; Go, S. H.; Choi, M.; Jang, Y. P.. Analytical quality by design (AQbD) approach to the development of analytical procedures for medicinal plants. Plants. 2022;11(21):2960.GOOGLE SCHOLAR
  16. 16.Patel, K. Y.; Dedania, Z. R.; Dedania, R. R.; Patel, U.. QbD approach to HPLC method development and validation of ceftriaxone sodium. Future Journal of Pharmaceutical Sciences. 2021;7(1):141.GOOGLE SCHOLAR
  17. 17.Patel, M.; Dwivedi, R.; Shah, U.; Kachhiya, H.. Development and application of RP--HPLC method for estimation and evaluation of stability of brinzolamide in ophthalmic formulation. Journal of Chemical Metrology. 2024;18(1).GOOGLE SCHOLAR
  18. 18.Pena-Pereira, F.; Wojnowski, W.; Tobiszewski, M.. AGREE—Analytical GREEnness metric approach and software. Analytical chemistry. 2020;92(14):10076–10082.GOOGLE SCHOLAR
  19. 19.Płotka-Wasylka, J.; Wojnowski, W.. Complementary green analytical procedure index (ComplexGAPI) and software. Green Chemistry. 2021;23(21):8657–8665.GOOGLE SCHOLAR
  20. 20.Rabadiya, V. A.; Shah, N.; Akabari, A. H.. Eco-friendly and stability-indicating HPTLC method for the estimation of Carvedilol in pharmaceutical dosage forms: A greenness assessment using NEMI scale, AGREE, and White Analytical Chemistry. Green Analytical Chemistry. 2025;13:100237.GOOGLE SCHOLAR
  21. 21.Sanjay, S. S.; Alegaon, S. G.; Palled, M. S.. Development and validation of isoniazid in bulk and pharmaceutical dosage forms by uflc method. Int. J. Pharma. Res. Health. Sci. 2019;7(1):2904–2908.GOOGLE SCHOLAR
  22. 22.Shetti, P.; Jalalpure, S. S.. A single robust stability-indicating RP-HPLC analytical tool for apigenin quantification in bulk powder and in nanoliposomes: a novel approach. Future Journal of Pharmaceutical Sciences. 2021;7(1):122.GOOGLE SCHOLAR
  23. 23.Shetti, P.; Jalalpure, S. S.. Optimization of a validated UV-spectrophotometric methodology for assessment of Apigenin in bulk powder. Indian J Pharmac Educ Res. 2022;56(1):281–286.GOOGLE SCHOLAR
  24. 24.Shivabasappa, P. M.; Mardolkar, S.; Suryawanshi, S.; Sanjay, M. K. C.; Jalalpure, S. S.. New validated Ultra High performance liquid chromatographic method for estimation of Ranolazine hydrochloride. Pharma Journal. 2019;8(7):382–5.GOOGLE SCHOLAR
  25. 25.Salokhe, A. S.; Malkar, S.; Mangule, S.; Palled, M. S.; Suryawanshi, S. S.; Dandagi, P. M.. Validated Area Under Curve and Zero Order Spectroscopic Methods for Estimation of Agomelatine in Bulk and Pharmaceutical Tablet Dosage Form. Biomedical and Pharmacology Journal. 2022;15(3):1337–1348.GOOGLE SCHOLAR
  26. 26.Suryawanshi, S. S.; Palled, M. S.. Box-Behnken design assisted optimization and standardization of chromatographic methodology for quality assessment of metformin: analytical quality by design avenue. Indian J. Pharm. Educ. Res. 2022;56(2s):s152–s162.GOOGLE SCHOLAR
  27. 27.Yin, L.; Yu, L.; Guo, Y.; Wang, C.; Ge, Y.; Zheng, X. et al. Green analytical chemistry metrics for evaluating the greenness of analytical procedures. Journal of Pharmaceutical Analysis. 2024;14(11):101013.GOOGLE SCHOLAR
  28. 28.Zokande, S. S.; Inamdar, D. K.; Gosar, D. A.; Mane, V.. Degradation Profile of Nepafenac Ophthalmic Suspension and Accurate Structural Characterization of 8-Benzoyl-1, 2-Dihydrocinnolin-3 (4h)-One Through Forced Degradation and Spectral Studies. Available at SSRN 5090590.GOOGLE SCHOLAR

Cite this article

SELECT FORMAT

Patil, D. R., Palled, M., Suryawanshi, S. S., Shetti, P. P., Patil, V., Bhingurde, T., Gawas, S., Dsouza, R., Bhogan, S., Hirakal, R., Bandekar, S., & Gavali, V. (2026). Integration of Green Chemistry Approach for Development of Box-Behnken Design Assisted RP-HPLC Method for Estimation of Nepafenac in Ophthalmic Dosage Form: A QbD Supported Degradation Approach. International Journal of Pharmaceutical Investigation, 16(4), 1578–1592. https://doi.org/10.5530/ijpi.20260266