Article

An experimental spinal cord injury rat model using customized impact device: A cost-effective approach

Vijayaprakash K.M1★, Sridharan N.2★ Corresponding author

  1. 1Centre for Tissue Engineering and Regeneration, Frontier Mediville (Special Economic Zone), Frontier Lifeline Pvt Ltd., A Unit of Dr.KM. Cherian Heart Foundation, Elavoor, Gummidipoondi, India.
  2. 2Department of Anatomy, Madras Medical College, The Tamilnadu Dr.M.G.R. Medical University, Chennai, Tamilnadu, India.

CORRESPONDENCE

Vijayaprakash K.M

Centre for Tissue Engineering and Regeneration, Frontier Mediville (Special Economic Zone), Frontier Lifeline Pvt Ltd., A Unit of Dr.KM. Cherian Heart Foundation, Elavoor, Gummidipoondi, India.

vijaymolbio@gmail.com

Volume 4, Issue 3 · pp. 211–213 · PUBLISHED 2013 · DOI: 10.4103/0976-500X.114607

View on JPP original site ↗

ABSTRACT

Till date, NYU MASCIS (New York University, Multicenter Animal Spinal Cord Injury Study) impactor and Ohio State University electromagnetic spinal cord injury device impactor were under use for simulating an experimental spinal cord injury in rodents; functional recovery being assessed through Basso, Beattie and Bresnahan (BBB) scoring method which is an open field behavior based scoring system. Although, the cited impactors are state‑of‑art devices, affordability to scientists in developing and under developed countries is questionable. Since the acquisition of these impact devices are expensive, we designed a customized impact device based on the requirement, satisfying all the parameters to withstand a standard animal model for contusion type of spinal cord injury at the thoracic level without compromising the lesion reproducibility. Here, a spinal cord contusion is created using a blunt‑force impactor in male Wistar rats. Our method gave consistent lesion effects as evaluated by behavior scoring methods. All the animals showed equal degree of performance in tests like narrow beam, inclined plane and horizontal ladder and in BBB scores (open field locomotor test). The aim of presenting our experience is to reinstate the fact that lack of affordability to get sophisticated instrumentation need not be a hurdle in the pursuit of science.

KEYWORDS

Open in new tab

REFERENCES

As published

Showing references and in-text citations exactly as published.

    Cite this article

    SELECT FORMAT

    K.M, V., & N., S. (2013). An experimental spinal cord injury rat model using customized impact device: A cost-effective approach. Journal of Pharmacology and Pharmacotherapeutics, 4(3), 211–213. https://doi.org/10.4103/0976-500X.114607