Article

LC-MS/MS Analytical Method Development and Validation for Determining Vinamidinium HexafluoroPhosphate Impurity in Etoricoxib

Satish Ganta1, T Siva Rao1★, K Rama Srinivas2, Pallapati Suman1★ Corresponding author

  1. 1Department of Chemistry, Andhra University, Visakhapatnam, Andhra Pradesh, INDIA.
  2. 2Department of Quality Control, Aurobindo Pharma Limited, Hyderabad, Telangana, INDIA.

CORRESPONDENCE

T Siva Rao

Prof. T. Siva Rao,Department of Chemistry, Andhra University, Visakhapatnam, Andhra Pradesh, INDIA.

sivaraoau@gmail.com

Received: 15-12-2022; Revised: 10-03-2023; Accepted: 16-04-2023.

Volume 57, Issue 3 · pp. 883–889 · PUBLISHED 2023 · DOI: 10.5530/ijper.57.3.106

View on IJPER original site ↗

ABSTRACT

Background and Aim: Process impurities may adversely affect the efficacy, excellent quality, and safety of pharmaceutical drugs. Ultimately, the purpose of this research work was to develop and validate a LC-MS/MS-based method for determining the Vinamidinium hexafluorophosphate impurity (VHP) in Etoricoxib in a simple, specific, accurate, and precise manner. Materials and Methods: To elute the Vinamidinium hexafluorophosphate impurity in Etoricoxib at a flow rate of 0.5mL/min within 20.0 min of runtime, a Symmetry Shield RP18, 5µm column with a 150 x 3.9 mm internal diameter was utilized in binary gradient mode. The buffer solution, which contained formic acid (0.1%) and acetonitrile (100%), as well as a diluent solution of acetonitrile (50%) and water (50%), was used to achieve the chromatographic separation. A triple quadrupole mass spectrometer (Shimadzu LC/MS/MS 8040) in Multiple Reaction Monitoring (MRM) mode was needed to monitor the results. Results and Discussion: The method's linearity was evaluated at levels from 25% to 150%, and the R2 value was discovered to be 0.99. Sensitivity values of 0.04µg/g (LOD) and 0.13µg/g (LOQ) were established. The recovery of impurity levels of Vinamidinium hexafluorophosphate ranges from 70.0% to 130%. Linearity, specificity, accuracy, LOD, LOQ, and precision of the method were all validated. Within the assay variability limitations, it was found that the intra- and inter-day precision values were 0.67%, and 0.58%, respectively. Conclusion: According to ICH and FDA specifications, the optimized method was validated. The developed method was found to be appropriate for quantifying Vinamidinium hexafluorophosphate in Etoricoxib by employing LC-MS.

KEYWORDS

Open in new tab

REFERENCES

As published

Showing references and in-text citations exactly as published.

    Cite this article

    SELECT FORMAT

    Ganta, S., Rao, T. S., Srinivas, K. R., & Suman, P. (2023). LC-MS/MS Analytical Method Development and Validation for Determining Vinamidinium HexafluoroPhosphate Impurity in Etoricoxib. Indian Journal of Pharmaceutical Education and Research, 57(3), 883–889. https://doi.org/10.5530/ijper.57.3.106