Quality-by-Design Optimization of Biotin-Coated Tetronic® 1107 Polymersomes for Carboplatin Delivery in Non-Small Cell Lung Cancer
Nithyananth Muniswamy1, Sankar Veintramuthu1★, Malathi Sellappan2★ Corresponding author
- 1Department of Pharmaceutics, PSG College of Pharmacy (Affiliated to The Tamil Nadu Dr. MGR Medical University, Chennai), Coimbatore, Tamil Nadu, INDIA.
- 2Department of Pharmaceutical Analysis, PSG College of Pharmacy (Affiliated to The Tamil Nadu Dr. MGR Medical University, Chennai), Coimbatore, Tamil Nadu, INDIA.
CORRESPONDENCE
Sankar Veintramuthu
Department of Pharmaceutics, PSG College of Pharmacy (Affiliated to The Tamil Nadu Dr. MGR Medical University, Chennai), Coimbatore, Tamil Nadu, INDIA.
Received: 09-05-2025; Revised: 24-07-2025; Accepted: 15-09-2025.
Volume 17, Issue 4 · pp. 864–876 · PUBLISHED · DOI: 10.5530/jyp.20250096
ABSTRACT
Background:For driver-negative Non-Small Cell Lung Cancer (NSCLC), platinum-based chemotherapy remains standard; however, carboplatin efficacy is limited by poor tumour delivery and dose-limiting toxicity. In this study, we developed biotin-functionalised polymersomes encapsulating carboplatin to enhance carrier stability and enable selective tumour delivery via sodium-dependent multivitamin transporter uptake. Materials and Methods:A Box-Behnken design optimised Tetronic® 1107 polymersomes by modelling polymer concentration, temperature, and stirring time against particle size, zeta potential, and entrapment efficiency. The optimised formulation was characterised by dynamic light scattering (particle size distribution); atomic force and scanning electron microscopy (morphology); Fourier-transform infrared spectroscopy (interactions); differential scanning calorimetry (thermal behaviour); and powder X-ray diffraction (crystallinity). It was further evaluated for pH-dependent release and cytotoxicity in biotin-overexpressing A549 cells. Results:Box-Behnken optimisation yielded SMVT-targeted, biotin-functionalised Tetronic® 1107 polymersomes (PS = 246 nm; ZP = –26 mV; EE = 85%). FTIR, DSC, and XRD showed a preserved PEO/PPO matrix with amorphous carboplatin. AFM and SEM revealed a corrugated, biotin-rich corona. Release was sustained and pH-responsive, fitting the Weibull model (R²=0.93-0.97). In A549 cells, biotin-coated vesicles reduced the IC₅₀ 1.73-fold relative to free carboplatin (p< 0.05). Conclusion:Biotin-functionalised polymersomes improved carboplatin loading, stability, and tumour-targeted cytotoxicity, supporting their evaluation in vivofor NSCLC therapy.
KEYWORDS
REFERENCES
As publishedShowing references and in-text citations exactly as published.
Cite this article
SELECT FORMAT
Muniswamy, N., Veintramuthu, S., & Sellappan, M. (). Quality-by-Design Optimization of Biotin-Coated Tetronic® 1107 Polymersomes for Carboplatin Delivery in Non-Small Cell Lung Cancer. Journal of Young Pharmacists, 17(4), 864–876. https://doi.org/10.5530/jyp.20250096