Smart UV Derivative Spectrophotometric Methods for Simultaneous Determination of Metformin and Remogliflozin: Development, Validation and Application to the Formulation
Smart UV Derivative Spectrophotometric Methods for Simultaneous Determination of Metformin1, Remogliflozin: Development1, Validation Validation1, Application to the Formulation1
- 1Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Hofuf, Al-Ahsa, KSA.
- 2Department of Pharmaceutics, Vidya Siri College of Pharmacy, Off Sarjapura Road, Bangalore, Karnataka, INDIA.
- 3Department of Biotechnology and Food Technology, Durban University of Technology, Durban, SOUTH AFRICA.
- 4Department of Biomedical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Hofuf, Al-Ahsa, KSA.
CORRESPONDENCE
Received: 12-10-2020; Revised: 18-01-2021; Accepted: 21-02-2021.
Volume 55, Issue 1S · pp. S293–S302 · PUBLISHED 2021 · DOI: 10.5530/ijper.55.1s.62
ABSTRACT
Background: The result of pharmaceutical industry research for the new class and the new combination of drugs for the treatments of diabetes is the newly approved combination of metformin (MET) and remogliflozin (REM). For the quality control of this formulation, three smart, reproducible and non-sophisticated spectroscopic techniques were developed by modification of UV spectra. Materials and Methods: The first two methods were based on the measurements of the peak height of the third derivative and second derivative ratio spectra of MET and REM and the third method was the constant center spectrum subtraction method. Results: The proposed methods exhibited Beer’s law in the range of 2.5 to 30 μg/ml and 1 to 24 μg/ml for MET and REM correspondingly by all three methods. The mean percentage recovery was found to be in the range of 99.08% to 100.15% for MET and 98.73% to 100.27% for REM. Further, both analytes were quantified from the formulation using proposed spectroscopic methods with high accuracy. Comparison of all three methods with the reported HPLC method showed no variation in the assay outcomes in relation to accuracy and precision. Conclusion: The suggested techniques are simple, accurate and reproducible, hence could be used for regular quality control of formulation consisting of MET and REM.
KEYWORDS
REFERENCES
As publishedShowing references and in-text citations exactly as published.
Cite this article
SELECT FORMAT
Metformin, S. U. D. S. M. F. S. D. O., Development, R., Validation, V., & Formulation, A. T. T. (2021). Smart UV Derivative Spectrophotometric Methods for Simultaneous Determination of Metformin and Remogliflozin: Development, Validation and Application to the Formulation. Indian Journal of Pharmaceutical Education and Research, 55(1S), S293–S302. https://doi.org/10.5530/ijper.55.1s.62
