Article

Development of an RP-HPLC Method for Simultaneous Estimation of Remogliflozin, Metformin and Teneligliptin in Tablet Formulation

Dhwani Shah1★, Sejalben Patel2, Ujashkumar Shah2, Khooshbu Patel2, Kunjal Vegad1, Hirak Shah1★ Corresponding author

  1. 1Department of Quality Assurance and Pharmacognosy, Faculty of Pharmacy, Parul College of Pharmacy and Research, Parul University, Bopal, Ahmedabad, Gujarat, INDIA.
  2. 2Department of Quality Assurance and Pharma Chemistry, Faculty of Pharmacy, Nootan Pharmacy College, Sankalchand Patel University, Visnagar, Gujarat, INDIA.

CORRESPONDENCE

Dhwani Shah

Department of Quality Assurance and Pharmacognosy, Faculty of Pharmacy, Parul College of Pharmacy and Research, Parul University, Bopal, Ahmedabad, Gujarat, INDIA.

shahdhwani57@gmail.com

Received: 28-05-2025; Revised: 04-07-2025; Accepted: 15-09-2025.

Volume 60, Issue 2S · pp. s522–s532 · PUBLISHED · DOI: 10.5530/ijper.20260472

View on IJPER original site ↗

ABSTRACT

Objectives: A cost-effective and reliable RP-HPLC method was developed and validated for the simultaneous estimation of Remogliflozin, Metformin and Teneligliptin in Pharmaceutical dosage form. Materials and Methods: Using an ECO-C18 (15 mm*4.6 mm*5 μ (particle size)) column with a mobile phase consisting of 0.6 M Phosphate Buffer pH 3.5: ACN (Acetonitrile) 40:60 v/v, analysis was conducted at 222 nm with a flow rate of 1.0 mL/min. Results: The validation method followed ICH guidelines, demonstrating linearity with LOQ values of 4.79 µg/mL for Remogliflozin, 24.85 µg/mL for Metformin and 0.56 µg/mL for Teneligliptin. LOD values were determined as 1.43 µg/mL for Remogliflozin, 7.53 µg/mL for Metformin and 0.17 µg/mL for Teneligliptin, with correlation coefficients of 0.99 for all compounds. % Recovery ranged from 99.73% to 100.86% for Remogliflozin, 98.59% to 100.90% for Metformin and 100.11 to 100.89% for Teneligliptin, while relative standard deviation values for Replication, inter-intraday precision were all below 2%. Conclusion: The proposed method exhibited specificity, sensitivity, precision, accuracy, and robustness, making it suitable for routine analysis.

KEYWORDS

Open in new tab

REFERENCES

As published

Showing references and in-text citations exactly as published.

    Cite this article

    SELECT FORMAT

    Shah, D., Patel, S., Shah, U., Patel, K., Vegad, K., & Shah, H. (). Development of an RP-HPLC Method for Simultaneous Estimation of Remogliflozin, Metformin and Teneligliptin in Tablet Formulation. Indian Journal of Pharmaceutical Education and Research, 60(2S), s522–s532. https://doi.org/10.5530/ijper.20260472